Transcriptomics

Dataset Information

0

Pax versus tempus expression profile differences


ABSTRACT: The main aim of the study was to compare genome-wide gene expression profiles obtained from the two widely used commercially available whole blood RNA collection systems - PAXgeneTM and TempusTM tubes. Comparisons of present call rates, variances, correlations and influence of globin reduction across the two collection systems was performed using in vivo glucocorticoid stimulation in 24 peripheral blood samples from three individuals. Three healthy male volunteers aged 30-35 years with body mass index of 20-25 were enrolled in the study.1.5 mg dexamethasone stimulated peripheral blood samples were drawn 3 hours later. For each sample, duplicate measures of 2.5 ml and 3ml blood was collected in PAXgeneTM tubes (PreAnalytiX GmbH, Hombrechtikon, Switzerland) and TempusTM tubes (Applied Biosystems, Foster City, CA, USA) respectively. The PAXgeneTM and TempusTM tubes were stored for 2.5 hours at room temperature and then transferred to -20°C. Due to the lower RNA yield from the PAXgeneTM tubes, RNA from two PAXgeneTM tubes was pooled together for the experiment . Total RNA was isolated from whole blood stored in PAXgeneTM and TempusTM tubes according to the respective manufacturer's instructions. The PAXgeneTM samples were processed using the PAXgeneTM Blood RNA Kit based on the Quiagen method for column purification of nucleic acids (PreAnalytiX GmbH, Hombrechtikon, Switzerland, catalogue number 762174). The TempusTM samples were isolated using the TempusTM Spin RNA Isolation Kit (Applied Biosystems, Foster City, CA, USA, catalogue number 4380204). RNA quality was assessed using an Agilent 2100 Bioanalyzer (Agilent Technologies, Palo Alto, CA, USA). The concentration and purity of total RNA was independently assessed by 260/280 UV absorption ratios, respectively (Nanophotometer, Implen, Munich, Germany). RNA samples were divided into non-globin reduced and globin reduced groups. The GLOBINclearTM-Human Kit (Ambion, Inc., Texas, USA, catalogue number #AM1980) was used to remove globin mRNA. Sample amplification and labeling for both globin-reduced and non-reduced samples was performed using the IlluminaR TotalPrep RNA Amplification Kit (Ambion, Inc., Texas, USA, catalogue number AMIL1791).

ORGANISM(S): Homo sapiens

PROVIDER: GSE34039 | GEO | 2012/01/15

SECONDARY ACCESSION(S): PRJNA148083

REPOSITORIES: GEO

Similar Datasets

2012-01-15 | E-GEOD-34039 | biostudies-arrayexpress
2021-08-11 | E-MTAB-10527 | biostudies-arrayexpress
2010-11-17 | E-GEOD-25414 | biostudies-arrayexpress
2021-08-13 | GSE181970 | GEO
2016-11-15 | GSE89021 | GEO
2020-06-01 | GSE123658 | GEO
2021-09-03 | GSE183073 | GEO
2009-01-30 | GSE13292 | GEO
2020-04-03 | E-MTAB-8858 | biostudies-arrayexpress
2020-02-03 | GSE131526 | GEO