{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["43(1)"],"submitter":["Consejo A"],"pubmed_abstract":["<h4>Purpose</h4>To study the effect of different soft contact lens (CL) materials during short-term wear on corneal tissue.<h4>Methods</h4>Twenty-two healthy participants wore both silicone hydrogel (MyDay, CooperVision) and hydrogel soft CLs (Biomedics 1 day extra, CooperVision) for 8 h per lens. In each session, Scheimpflug images were captured before and immediately after CL removal. Images were analysed using the densitometry distribution analysis, a technique from which two parameters, α (corneal transparency) and β (corneal homogeneity), were estimated. In addition, the central corneal thickness changes after CL wear and the influence of the CL material on corneal transparency were evaluated.<h4>Results</h4>The β parameter (homogeneity) increased by 5% after wearing both CL materials"],"journal":["Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)"],"pagination":["35-45"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC10099478"],"repository":["biostudies-literature"],"pubmed_title":["Corneal tissue changes following short-term soft contact lens wear of different materials."],"pmcid":["PMC10099478"],"pubmed_authors":["Remon L","Consejo A","Trillo-Moreno I"],"additional_accession":[]},"is_claimable":false,"name":"Corneal tissue changes following short-term soft contact lens wear of different materials.","description":"<h4>Purpose</h4>To study the effect of different soft contact lens (CL) materials during short-term wear on corneal tissue.<h4>Methods</h4>Twenty-two healthy participants wore both silicone hydrogel (MyDay, CooperVision) and hydrogel soft CLs (Biomedics 1 day extra, CooperVision) for 8 h per lens. In each session, Scheimpflug images were captured before and immediately after CL removal. Images were analysed using the densitometry distribution analysis, a technique from which two parameters, α (corneal transparency) and β (corneal homogeneity), were estimated. In addition, the central corneal thickness changes after CL wear and the influence of the CL material on corneal transparency were evaluated.<h4>Results</h4>The β parameter (homogeneity) increased by 5% after wearing both CL materials","dates":{"release":"2023-01-01T00:00:00Z","publication":"2023 Jan","modification":"2025-04-22T04:59:45.289Z","creation":"2025-04-05T21:14:50.062Z"},"accession":"S-EPMC10099478","cross_references":{"pubmed":["36408647"],"doi":["10.1111/opo.13067"]}}