{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["6(4)"],"submitter":["Stone GW"],"pubmed_abstract":["<h4>Background</h4>Reshaping the dilated left ventricle using a surgically implanted papillary muscle sling has been shown to provide long-term improvement in cardiac function compared to annuloplasty alone in patients with systolic heart failure. A papillary muscle sling which can be implanted via a transcatheter approach has the potential to make this treatment more widely available to patients.<h4>Methods</h4>The Vsling transcatheter papillary muscle sling device was evaluated in a chronic animal model (sacrificed at 30 and 90 days), in a simulator, and in a human cadaver.<h4>Results</h4>The Vsling device was successfully implanted in 10 pigs, 6 simulator procedures, and 1 human cadaver. Procedure complexity and device usability were rated as reasonable or better by 6 interventional car"],"journal":["Structural heart : the journal of the Heart Team"],"pagination":["100075"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC10242562"],"repository":["biostudies-literature"],"pubmed_title":["Description, Feasibility, and Histological Assessment of the Vsling, a Novel Transcatheter Ventricular Repair Device."],"pmcid":["PMC10242562"],"pubmed_authors":["Stone GW","Manash B","Neustadter D","Sievert H","Virmani R","Shaler LW"],"additional_accession":[]},"is_claimable":false,"name":"Description, Feasibility, and Histological Assessment of the Vsling, a Novel Transcatheter Ventricular Repair Device.","description":"<h4>Background</h4>Reshaping the dilated left ventricle using a surgically implanted papillary muscle sling has been shown to provide long-term improvement in cardiac function compared to annuloplasty alone in patients with systolic heart failure. A papillary muscle sling which can be implanted via a transcatheter approach has the potential to make this treatment more widely available to patients.<h4>Methods</h4>The Vsling transcatheter papillary muscle sling device was evaluated in a chronic animal model (sacrificed at 30 and 90 days), in a simulator, and in a human cadaver.<h4>Results</h4>The Vsling device was successfully implanted in 10 pigs, 6 simulator procedures, and 1 human cadaver. Procedure complexity and device usability were rated as reasonable or better by 6 interventional car","dates":{"release":"2022-01-01T00:00:00Z","publication":"2022 Aug","modification":"2025-04-19T07:21:16.085Z","creation":"2024-12-04T08:14:13.203Z"},"accession":"S-EPMC10242562","cross_references":{"pubmed":["37288331"],"doi":["10.1016/j.shj.2022.100075"]}}