{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Oertli JM"],"funding":["Swiss National Science Foundation","Wellcome Trust"],"pagination":["18"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC10732091"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["12(12)"],"pubmed_abstract":["<h4>Purpose</h4>The purpose of this study was to establish and validate a novel fundus-controlled dark-adaptometry method.<h4>Methods</h4>We developed a custom dark-adaptometry software for the S-MAIA device using the open-perimetry-interface. In the validation-substudy, participants underwent dark-adaptometry testing with a comparator device (MonCvONE, 59% rhodopsin bleach, cyan and red stimuli centered at 2 degrees, 4 degrees, and 6 degrees eccentricity). Following a brief break (approximately 5 minutes), the participants were bleached again and underwent dark-adaptometry testing with the S-MAIA device (same loci). In the retest reliability-substudy, participants were tested twice with the S-MAIA device (same loci as above). Nonlinear curve fitting was applied to extract dark-adaptation "],"journal":["Translational vision science & technology"],"pubmed_title":["Establishing Fully-Automated Fundus-Controlled Dark Adaptometry: A Validation and Retest-Reliability Study."],"pmcid":["PMC10732091"],"funding_grant_id":["201165","310030"],"pubmed_authors":["Oertli JM","Jeffrey BG","Pfau M","Pfau K","Scholl HPN"],"additional_accession":[]},"is_claimable":false,"name":"Establishing Fully-Automated Fundus-Controlled Dark Adaptometry: A Validation and Retest-Reliability Study.","description":"<h4>Purpose</h4>The purpose of this study was to establish and validate a novel fundus-controlled dark-adaptometry method.<h4>Methods</h4>We developed a custom dark-adaptometry software for the S-MAIA device using the open-perimetry-interface. In the validation-substudy, participants underwent dark-adaptometry testing with a comparator device (MonCvONE, 59% rhodopsin bleach, cyan and red stimuli centered at 2 degrees, 4 degrees, and 6 degrees eccentricity). Following a brief break (approximately 5 minutes), the participants were bleached again and underwent dark-adaptometry testing with the S-MAIA device (same loci). In the retest reliability-substudy, participants were tested twice with the S-MAIA device (same loci as above). Nonlinear curve fitting was applied to extract dark-adaptation ","dates":{"release":"2023-01-01T00:00:00Z","publication":"2023 Dec","modification":"2026-05-28T19:11:47.962Z","creation":"2025-04-05T20:12:24.762Z"},"accession":"S-EPMC10732091","cross_references":{"pubmed":["38112496"],"doi":["10.1167/tvst.12.12.18"]}}