{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["8(1)"],"submitter":["Shah R"],"pubmed_abstract":["<h4>Background</h4>The FROM-16 is a generic family quality of life (QoL) instrument that measures the QoL impact of patients' disease on their family members/partners. The study aimed to assess the responsiveness of FROM-16 to change and determine Minimal Important Change (MIC).<h4>Methods</h4>Responsiveness and MIC for FROM-16 were assessed prospectively with patients and their family members recruited from outpatient departments of the University Hospital Wales and University Hospital Llandough, Cardiff, United Kingdom. Patients completed the EQ-5D-3L and a global severity question (GSQ) online at baseline and at 3-month follow-up. Family members completed FROM-16 at baseline and a Global Rating of Change (GRC) in addition to FROM-16 at follow-up. Responsiveness was assessed using the distribution-based (effect size-ES, standardized response mean -SRM) and anchor-based (area under the receiver operating characteristics curve ROC-AUC) approaches and by testing hypotheses on expected correlation strength between FROM-16 change score and patient assessment tools (GSQ and EQ-5D). Cohen's criteria were used for assessing ES. The AUC ≥ 0.7 was considered a good measure of responsiveness. MIC was calculated using anchor-based (ROC analysis and adjusted predictive modelling) and distribution methods based on standard deviation (SD) and standard error of the measurement (SEM).<h4>Results</h4>Eighty-three patients with 15 different health conditions and their relatives completed baseline and follow-up questionnaires and were included in the responsiveness analysis. The mean FROM-16 change over 3 months = 1.43 (SD = 4.98). The mean patient EQ-5D change over 3 months = -0.059 (SD = 0.14). The responsiveness analysis showed that the FROM-16 was responsive to change (ES = 0.2, SRM = 0.3; p < 0.01). The ES and SRM of FROM-16 change score ranged from small (ES = 0.2; SRM = 0.3) for the distribution-based method to large (ES = 0.8, SRM = 0.85) for anchor-based methods. The AUC value was above 0.7, indicating good responsiveness. There was a significant positive correlation between the FROM-16 change scores and the patient's disease severity change scores (p < 0.001). The MIC analysis was based on data from 100 family members of 100 patients. The MIC value of 4 was suggested for FROM-16.<h4>Conclusions</h4>The results of this study confirm the longitudinal validity of FROM-16 which refers to the degree to which an instrument is able to measure change in the construct to be measured. The results yield a MIC value of 4 for FROM-16. These psychometric attributes of the FROM-16 instrument are useful in both clinical research as well as clinical practice."],"journal":["Journal of patient-reported outcomes"],"pagination":["38"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC10965873"],"repository":["biostudies-literature"],"pubmed_title":["Responsiveness and minimal important change of the Family Reported Outcome Measure (FROM-16)."],"pmcid":["PMC10965873"],"pubmed_authors":["Allen H","Ali FM","Ingram JR","Nixon SJ","Finlay AY","Shah R","Otwombe K","Salek MS","Nixon M"],"additional_accession":[]},"is_claimable":false,"name":"Responsiveness and minimal important change of the Family Reported Outcome Measure (FROM-16).","description":"<h4>Background</h4>The FROM-16 is a generic family quality of life (QoL) instrument that measures the QoL impact of patients' disease on their family members/partners. The study aimed to assess the responsiveness of FROM-16 to change and determine Minimal Important Change (MIC).<h4>Methods</h4>Responsiveness and MIC for FROM-16 were assessed prospectively with patients and their family members recruited from outpatient departments of the University Hospital Wales and University Hospital Llandough, Cardiff, United Kingdom. Patients completed the EQ-5D-3L and a global severity question (GSQ) online at baseline and at 3-month follow-up. Family members completed FROM-16 at baseline and a Global Rating of Change (GRC) in addition to FROM-16 at follow-up. Responsiveness was assessed using the distribution-based (effect size-ES, standardized response mean -SRM) and anchor-based (area under the receiver operating characteristics curve ROC-AUC) approaches and by testing hypotheses on expected correlation strength between FROM-16 change score and patient assessment tools (GSQ and EQ-5D). Cohen's criteria were used for assessing ES. The AUC ≥ 0.7 was considered a good measure of responsiveness. MIC was calculated using anchor-based (ROC analysis and adjusted predictive modelling) and distribution methods based on standard deviation (SD) and standard error of the measurement (SEM).<h4>Results</h4>Eighty-three patients with 15 different health conditions and their relatives completed baseline and follow-up questionnaires and were included in the responsiveness analysis. The mean FROM-16 change over 3 months = 1.43 (SD = 4.98). The mean patient EQ-5D change over 3 months = -0.059 (SD = 0.14). The responsiveness analysis showed that the FROM-16 was responsive to change (ES = 0.2, SRM = 0.3; p < 0.01). The ES and SRM of FROM-16 change score ranged from small (ES = 0.2; SRM = 0.3) for the distribution-based method to large (ES = 0.8, SRM = 0.85) for anchor-based methods. The AUC value was above 0.7, indicating good responsiveness. There was a significant positive correlation between the FROM-16 change scores and the patient's disease severity change scores (p < 0.001). The MIC analysis was based on data from 100 family members of 100 patients. The MIC value of 4 was suggested for FROM-16.<h4>Conclusions</h4>The results of this study confirm the longitudinal validity of FROM-16 which refers to the degree to which an instrument is able to measure change in the construct to be measured. The results yield a MIC value of 4 for FROM-16. These psychometric attributes of the FROM-16 instrument are useful in both clinical research as well as clinical practice.","dates":{"release":"2024-01-01T00:00:00Z","publication":"2024 Mar","modification":"2025-04-27T03:15:16.935Z","creation":"2025-04-06T18:45:53.871Z"},"accession":"S-EPMC10965873","cross_references":{"pubmed":["38530614"],"doi":["10.1186/s41687-024-00703-1"]}}