{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Szpot P"],"funding":["Wroclaw Medical University"],"pagination":["4585"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC11477679"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["29(19)"],"pubmed_abstract":["Betablockers are one of the most frequently used medications in cardiology. They can lead to fatal drops in blood pressure and heart rhythm disturbances. Death is functional, and poisoning with this group of drugs can be difficult to detect. The liquid-liquid extraction (LLE) method developed using ethyl acetate at pH 9 successfully identified 18 β-blockers in human blood. The method's limit of quantification (LOQ) was in the range of 0.1 to 0.5 ng/mL. No carryover of substances between samples was detected, and no interfering ion current signals were observed in the biological samples at the retention times of the compounds or internal standards. All compounds had a coefficient of determination (R<sup>2</sup>) above 0.995. Intraday and interday precision (RSD%) and accuracy (RE%) for low "],"journal":["Molecules (Basel, Switzerland)"],"pubmed_title":["Application of UHPLC-QqQ-MS/MS Method for Quantification of Beta-Adrenergic Blocking Agents (β-Blockers) in Human Postmortem Specimens."],"pmcid":["PMC11477679"],"funding_grant_id":["SUBK.A120.23.062"],"pubmed_authors":["Tusiewicz K","Wachelko O","Zawadzki M","Szpot P"],"additional_accession":[]},"is_claimable":false,"name":"Application of UHPLC-QqQ-MS/MS Method for Quantification of Beta-Adrenergic Blocking Agents (β-Blockers) in Human Postmortem Specimens.","description":"Betablockers are one of the most frequently used medications in cardiology. They can lead to fatal drops in blood pressure and heart rhythm disturbances. Death is functional, and poisoning with this group of drugs can be difficult to detect. The liquid-liquid extraction (LLE) method developed using ethyl acetate at pH 9 successfully identified 18 β-blockers in human blood. The method's limit of quantification (LOQ) was in the range of 0.1 to 0.5 ng/mL. No carryover of substances between samples was detected, and no interfering ion current signals were observed in the biological samples at the retention times of the compounds or internal standards. All compounds had a coefficient of determination (R<sup>2</sup>) above 0.995. Intraday and interday precision (RSD%) and accuracy (RE%) for low ","dates":{"release":"2024-01-01T00:00:00Z","publication":"2024 Sep","modification":"2025-04-04T02:19:50.046Z","creation":"2025-04-04T02:19:50.046Z"},"accession":"S-EPMC11477679","cross_references":{"pubmed":["39407515"],"doi":["10.3390/molecules29194585"]}}