{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["17(1)"],"submitter":["Bai Y"],"pubmed_abstract":["This study presents a breakthrough in flexible strain sensor technology with the development of an ultra-high sensitivity and wide-range sensor, addressing the critical challenge of reconciling sensitivity with measurement range. Inspired by the structure of bamboo slips, we introduce a novel approach that utilises liquid metal to modulate the electrical pathways within a cracked platinum fabric electrode. The resulting sensor demonstrates a gauge factor greater than 10<sup>8</sup> and a strain measurement capability exceeding 100%. The integration of patterned liquid metal enables customisable tuning of the sensor's response, while the porous fabric structure ensures superior comfort and air permeability for the wearer. Our design not only optimises the sensor's performance but also enhan"],"journal":["Nano-micro letters"],"pagination":["64"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC11570575"],"repository":["biostudies-literature"],"pubmed_title":["Flexible Strain Sensors with Ultra-High Sensitivity and Wide Range Enabled by Crack-Modulated Electrical Pathways."],"pmcid":["PMC11570575"],"pubmed_authors":["Qu S","Zhang F","Huang Y","Bai Y","Zhou Y","Yin M","Li K","Yin L","Wu X"],"additional_accession":[]},"is_claimable":false,"name":"Flexible Strain Sensors with Ultra-High Sensitivity and Wide Range Enabled by Crack-Modulated Electrical Pathways.","description":"This study presents a breakthrough in flexible strain sensor technology with the development of an ultra-high sensitivity and wide-range sensor, addressing the critical challenge of reconciling sensitivity with measurement range. Inspired by the structure of bamboo slips, we introduce a novel approach that utilises liquid metal to modulate the electrical pathways within a cracked platinum fabric electrode. The resulting sensor demonstrates a gauge factor greater than 10<sup>8</sup> and a strain measurement capability exceeding 100%. The integration of patterned liquid metal enables customisable tuning of the sensor's response, while the porous fabric structure ensures superior comfort and air permeability for the wearer. Our design not only optimises the sensor's performance but also enhan","dates":{"release":"2024-01-01T00:00:00Z","publication":"2024 Nov","modification":"2026-03-17T16:14:01.463Z","creation":"2025-04-04T00:47:48.785Z"},"accession":"S-EPMC11570575","cross_references":{"pubmed":["39551898"],"doi":["10.1007/s40820-024-01571-6"]}}