<HashMap><database>biostudies-literature</database><scores/><additional><submitter>Seo D</submitter><funding>Korea Research Institute of Ships and Ocean Engineering</funding><pagination>721</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC11673239</full_dataset_link><repository>biostudies-literature</repository><omics_type>Unknown</omics_type><volume>9(12)</volume><pubmed_abstract>Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber. The optical signal emitted by the phosphor is measured using a camera. An experiment was conducted to apply an external force to the reactive part using a push-pull force gauge sensor to confirm the performance of the proposed sensor. The optical signal emitted by the phosphor was obtained using an image sensor, and a quantitative value was calculated using image analysis. A simulation enviro</pubmed_abstract><journal>Biomimetics (Basel, Switzerland)</journal><pubmed_title>Optical Flow Sensor with Fluorescent-Conjugated Hyperelastic Pillar: A Biomimetic Approach.</pubmed_title><pmcid>PMC11673239</pmcid><funding_grant_id>PES5191</funding_grant_id><pubmed_authors>Seo D</pubmed_authors><pubmed_authors>Lee S</pubmed_authors><pubmed_authors>Park J</pubmed_authors><pubmed_authors>Yoon S</pubmed_authors><pubmed_authors>Oh S</pubmed_authors><pubmed_authors>Han S</pubmed_authors><pubmed_authors>Byun SH</pubmed_authors></additional><is_claimable>false</is_claimable><name>Optical Flow Sensor with Fluorescent-Conjugated Hyperelastic Pillar: A Biomimetic Approach.</name><description>Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber. The optical signal emitted by the phosphor is measured using a camera. An experiment was conducted to apply an external force to the reactive part using a push-pull force gauge sensor to confirm the performance of the proposed sensor. The optical signal emitted by the phosphor was obtained using an image sensor, and a quantitative value was calculated using image analysis. A simulation enviro</description><dates><release>2024-01-01T00:00:00Z</release><publication>2024 Nov</publication><modification>2025-04-04T01:32:50.285Z</modification><creation>2025-04-04T01:32:50.285Z</creation></dates><accession>S-EPMC11673239</accession><cross_references><pubmed>39727725</pubmed><doi>10.3390/biomimetics9120721</doi></cross_references></HashMap>