{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["97(15)"],"submitter":["Pieczonka SA"],"funding":["Mars Petcare UK"],"pubmed_abstract":["Given the long hardware lifespan, fixed installation, and comparatively high investment required to procure them, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) instruments tend to have a long operational life. The field is constantly evolving with rapidly advancing instrumental developments, and FT-ICR research groups work with a range of instrument designs from different generations. Consequently, compositional spectra comparability between instruments is a critical concern in FT-ICR-MS, particularly due to the variability introduced by commonly used direct infusion methods. This study demonstrates interlaboratory comparability of FT-ICR-MS molecular profiles using a 12 T solariX with an Infinity Cell and a 7 T scimaX with a ParaCell, with closely matched sample "],"journal":["Analytical chemistry"],"pagination":["8491-8498"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC12019771"],"repository":["biostudies-literature"],"pubmed_title":["Harmonization of FT-ICR-MS Instruments for Interoperable Multi-Laboratory Comprehensive Compositional Profiling."],"pmcid":["PMC12019771"],"pubmed_authors":["Marshall JW","Thomas MJ","Schmitt-Kopplin P","Pieczonka SA"],"additional_accession":[]},"is_claimable":false,"name":"Harmonization of FT-ICR-MS Instruments for Interoperable Multi-Laboratory Comprehensive Compositional Profiling.","description":"Given the long hardware lifespan, fixed installation, and comparatively high investment required to procure them, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) instruments tend to have a long operational life. The field is constantly evolving with rapidly advancing instrumental developments, and FT-ICR research groups work with a range of instrument designs from different generations. Consequently, compositional spectra comparability between instruments is a critical concern in FT-ICR-MS, particularly due to the variability introduced by commonly used direct infusion methods. This study demonstrates interlaboratory comparability of FT-ICR-MS molecular profiles using a 12 T solariX with an Infinity Cell and a 7 T scimaX with a ParaCell, with closely matched sample ","dates":{"release":"2025-01-01T00:00:00Z","publication":"2025 Apr","modification":"2025-06-26T03:05:41.547Z","creation":"2025-06-26T03:05:41.547Z"},"accession":"S-EPMC12019771","cross_references":{"pubmed":["40208963"],"doi":["10.1021/acs.analchem.5c00488"]}}