<HashMap><database>biostudies-literature</database><scores/><additional><omics_type>Unknown</omics_type><volume>97(15)</volume><submitter>Pieczonka SA</submitter><funding>Mars Petcare UK</funding><pubmed_abstract>Given the long hardware lifespan, fixed installation, and comparatively high investment required to procure them, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) instruments tend to have a long operational life. The field is constantly evolving with rapidly advancing instrumental developments, and FT-ICR research groups work with a range of instrument designs from different generations. Consequently, compositional spectra comparability between instruments is a critical concern in FT-ICR-MS, particularly due to the variability introduced by commonly used direct infusion methods. This study demonstrates interlaboratory comparability of FT-ICR-MS molecular profiles using a 12 T solariX with an Infinity Cell and a 7 T scimaX with a ParaCell, with closely matched sample </pubmed_abstract><journal>Analytical chemistry</journal><pagination>8491-8498</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC12019771</full_dataset_link><repository>biostudies-literature</repository><pubmed_title>Harmonization of FT-ICR-MS Instruments for Interoperable Multi-Laboratory Comprehensive Compositional Profiling.</pubmed_title><pmcid>PMC12019771</pmcid><pubmed_authors>Marshall JW</pubmed_authors><pubmed_authors>Thomas MJ</pubmed_authors><pubmed_authors>Schmitt-Kopplin P</pubmed_authors><pubmed_authors>Pieczonka SA</pubmed_authors></additional><is_claimable>false</is_claimable><name>Harmonization of FT-ICR-MS Instruments for Interoperable Multi-Laboratory Comprehensive Compositional Profiling.</name><description>Given the long hardware lifespan, fixed installation, and comparatively high investment required to procure them, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) instruments tend to have a long operational life. The field is constantly evolving with rapidly advancing instrumental developments, and FT-ICR research groups work with a range of instrument designs from different generations. Consequently, compositional spectra comparability between instruments is a critical concern in FT-ICR-MS, particularly due to the variability introduced by commonly used direct infusion methods. This study demonstrates interlaboratory comparability of FT-ICR-MS molecular profiles using a 12 T solariX with an Infinity Cell and a 7 T scimaX with a ParaCell, with closely matched sample </description><dates><release>2025-01-01T00:00:00Z</release><publication>2025 Apr</publication><modification>2025-06-26T03:05:41.547Z</modification><creation>2025-06-26T03:05:41.547Z</creation></dates><accession>S-EPMC12019771</accession><cross_references><pubmed>40208963</pubmed><doi>10.1021/acs.analchem.5c00488</doi></cross_references></HashMap>