{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Brobbin E"],"funding":["NIHR ARC South London","Medical Research Council","National Institute for Health Research (NIHR)"],"pagination":["agad068"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC12461868"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["59(1)"],"pubmed_abstract":["The development of transdermal alcohol sensors (TASs) presents a new method to monitor alcohol consumption with the ability to objectively measure data 24/7. We aimed to evaluate the accuracy of two TASs (BACtrack Skyn and Smart Start BARE) in a laboratory setting. Thirty-two adults received a dose of ethanol 0.56 g/kg body weight as a 20% solution while wearing the two TASs and provided Breath Alcohol Concentration (BrAC) measurements for 3.5 h postalcohol consumption. Pearson's correlations and repeated measures analysis of variance tests were conducted on the peak, time-to-peak, and area under the curve data. Bland-Altman plots were derived. A time series analysis and cross-correlations were conducted to adjust for time lag. Both TASs were able to detect alcohol and increase within 20 m"],"journal":["Alcohol and alcoholism (Oxford, Oxfordshire)"],"pubmed_title":["Accuracy of transdermal alcohol monitoring devices in a laboratory setting."],"pmcid":["PMC12461868"],"funding_grant_id":["RP-PG-0609-10162","G0701818","NF-SI-0616-10077","NIHR202440","NIHR200152","NIHR-INF-1451","13/86/03"],"pubmed_authors":["Coulton S","Brobbin E","Deluca P","Drummond C"],"additional_accession":[]},"is_claimable":false,"name":"Accuracy of transdermal alcohol monitoring devices in a laboratory setting.","description":"The development of transdermal alcohol sensors (TASs) presents a new method to monitor alcohol consumption with the ability to objectively measure data 24/7. We aimed to evaluate the accuracy of two TASs (BACtrack Skyn and Smart Start BARE) in a laboratory setting. Thirty-two adults received a dose of ethanol 0.56 g/kg body weight as a 20% solution while wearing the two TASs and provided Breath Alcohol Concentration (BrAC) measurements for 3.5 h postalcohol consumption. Pearson's correlations and repeated measures analysis of variance tests were conducted on the peak, time-to-peak, and area under the curve data. Bland-Altman plots were derived. A time series analysis and cross-correlations were conducted to adjust for time lag. Both TASs were able to detect alcohol and increase within 20 m","dates":{"release":"2024-01-01T00:00:00Z","publication":"2024 Jan","modification":"2026-06-03T20:27:21.354Z","creation":"2026-06-01T03:06:07.794Z"},"accession":"S-EPMC12461868","cross_references":{"pubmed":["37873967"],"doi":["10.1093/alcalc/agad068"]}}