<HashMap><database>biostudies-literature</database><scores/><additional><submitter>Brobbin E</submitter><funding>NIHR ARC South London</funding><funding>Medical Research Council</funding><funding>National Institute for Health Research (NIHR)</funding><pagination>agad068</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC12461868</full_dataset_link><repository>biostudies-literature</repository><omics_type>Unknown</omics_type><volume>59(1)</volume><pubmed_abstract>The development of transdermal alcohol sensors (TASs) presents a new method to monitor alcohol consumption with the ability to objectively measure data 24/7. We aimed to evaluate the accuracy of two TASs (BACtrack Skyn and Smart Start BARE) in a laboratory setting. Thirty-two adults received a dose of ethanol 0.56 g/kg body weight as a 20% solution while wearing the two TASs and provided Breath Alcohol Concentration (BrAC) measurements for 3.5 h postalcohol consumption. Pearson's correlations and repeated measures analysis of variance tests were conducted on the peak, time-to-peak, and area under the curve data. Bland-Altman plots were derived. A time series analysis and cross-correlations were conducted to adjust for time lag. Both TASs were able to detect alcohol and increase within 20 m</pubmed_abstract><journal>Alcohol and alcoholism (Oxford, Oxfordshire)</journal><pubmed_title>Accuracy of transdermal alcohol monitoring devices in a laboratory setting.</pubmed_title><pmcid>PMC12461868</pmcid><funding_grant_id>RP-PG-0609-10162</funding_grant_id><funding_grant_id>G0701818</funding_grant_id><funding_grant_id>NF-SI-0616-10077</funding_grant_id><funding_grant_id>NIHR202440</funding_grant_id><funding_grant_id>NIHR200152</funding_grant_id><funding_grant_id>NIHR-INF-1451</funding_grant_id><funding_grant_id>13/86/03</funding_grant_id><pubmed_authors>Coulton S</pubmed_authors><pubmed_authors>Brobbin E</pubmed_authors><pubmed_authors>Deluca P</pubmed_authors><pubmed_authors>Drummond C</pubmed_authors></additional><is_claimable>false</is_claimable><name>Accuracy of transdermal alcohol monitoring devices in a laboratory setting.</name><description>The development of transdermal alcohol sensors (TASs) presents a new method to monitor alcohol consumption with the ability to objectively measure data 24/7. We aimed to evaluate the accuracy of two TASs (BACtrack Skyn and Smart Start BARE) in a laboratory setting. Thirty-two adults received a dose of ethanol 0.56 g/kg body weight as a 20% solution while wearing the two TASs and provided Breath Alcohol Concentration (BrAC) measurements for 3.5 h postalcohol consumption. Pearson's correlations and repeated measures analysis of variance tests were conducted on the peak, time-to-peak, and area under the curve data. Bland-Altman plots were derived. A time series analysis and cross-correlations were conducted to adjust for time lag. Both TASs were able to detect alcohol and increase within 20 m</description><dates><release>2024-01-01T00:00:00Z</release><publication>2024 Jan</publication><modification>2026-06-03T20:27:21.354Z</modification><creation>2026-06-01T03:06:07.794Z</creation></dates><accession>S-EPMC12461868</accession><cross_references><pubmed>37873967</pubmed><doi>10.1093/alcalc/agad068</doi></cross_references></HashMap>