{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["15(1)"],"submitter":["Haider H"],"pubmed_abstract":["A probabilistic methodology assessed hydraulics, water consumption, distribution pumping, and households pumping from the ground to rooftop storage for energy consumption in 24/7 and 2-day supply scenarios in two distribution networks, each with 379 and 959 service connections and diverse topographies. A local market survey gathered the characteristics of thirty-two household-level pumps used in the area. Considering a per capita daily water consumption of 250 L, probabilistic analysis revealed that the daily operating time of household pumps varied from 0.155 to 0.17 h at the median and from 0.37 to 0.47 h at a 0.9 probability, highlighting variation in household sizes within the study region. The study observed 26% higher energy consumption with a 24/7 supply compared to a 2-day supply f"],"journal":["Scientific reports"],"pagination":["33157"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC12475210"],"repository":["biostudies-literature"],"pubmed_title":["A unified probabilistic energy and carbon footprint appraisal for intermittent water supply systems in arid regions."],"pmcid":["PMC12475210"],"pubmed_authors":["Hassan K","Alresheedi M","Ghumman AR","Haider H","Shafiquzzaman M","Mallick J"],"additional_accession":[]},"is_claimable":false,"name":"A unified probabilistic energy and carbon footprint appraisal for intermittent water supply systems in arid regions.","description":"A probabilistic methodology assessed hydraulics, water consumption, distribution pumping, and households pumping from the ground to rooftop storage for energy consumption in 24/7 and 2-day supply scenarios in two distribution networks, each with 379 and 959 service connections and diverse topographies. A local market survey gathered the characteristics of thirty-two household-level pumps used in the area. Considering a per capita daily water consumption of 250 L, probabilistic analysis revealed that the daily operating time of household pumps varied from 0.155 to 0.17 h at the median and from 0.37 to 0.47 h at a 0.9 probability, highlighting variation in household sizes within the study region. The study observed 26% higher energy consumption with a 24/7 supply compared to a 2-day supply f","dates":{"release":"2025-01-01T00:00:00Z","publication":"2025 Sep","modification":"2026-06-03T21:46:47.772Z","creation":"2026-05-02T03:09:10.466Z"},"accession":"S-EPMC12475210","cross_references":{"pubmed":["41006660"],"doi":["10.1038/s41598-025-18698-0"]}}