{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["11(1)"],"submitter":["Espina-Martin P"],"pubmed_abstract":["Ammonia (NH<sub>3</sub>) gas is primarily an agriculture atmospheric pollutant, and measuring near-emission sources is essential for understanding NH<sub>3</sub> emission plumes. Sensors in theory are attractive alternative monitoring methods due to their high-time data resolution, size, and lower costs; however, there are metrological and technical challenges. NH<sub>3</sub> sensors operating in the subppm range (typical of near-emission source concentrations) are relatively new to the market, and while promising, there are metrological and technical challenges, especially in outdoor environments. Six NH<sub>3</sub> sensors were evaluated under field conditions at a poultry house emission simulation site, Whim Bog, Scotland (3.4 g of NH<sub>3</sub> min<sup>-1</sup>). Five electrochemical "],"journal":["ACS omega"],"pagination":["917-929"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC12809547"],"repository":["biostudies-literature"],"pubmed_title":["Are Ammonia Sensors Ready for Outdoor Use?"],"pmcid":["PMC12809547"],"pubmed_authors":["Costello H","Deshpande AG","Yeung K","Pearson C","Mullinger NJ","Jones MR","Braban CF","Hernandez CM","Leeson SR","Nicoll R","Redon N","Twigg MM","Espina-Martin P","Spelman G"],"additional_accession":[]},"is_claimable":false,"name":"Are Ammonia Sensors Ready for Outdoor Use?","description":"Ammonia (NH<sub>3</sub>) gas is primarily an agriculture atmospheric pollutant, and measuring near-emission sources is essential for understanding NH<sub>3</sub> emission plumes. Sensors in theory are attractive alternative monitoring methods due to their high-time data resolution, size, and lower costs; however, there are metrological and technical challenges. NH<sub>3</sub> sensors operating in the subppm range (typical of near-emission source concentrations) are relatively new to the market, and while promising, there are metrological and technical challenges, especially in outdoor environments. Six NH<sub>3</sub> sensors were evaluated under field conditions at a poultry house emission simulation site, Whim Bog, Scotland (3.4 g of NH<sub>3</sub> min<sup>-1</sup>). Five electrochemical ","dates":{"release":"2026-01-01T00:00:00Z","publication":"2026 Jan","modification":"2026-06-12T04:54:04.426Z","creation":"2026-06-12T03:08:00.94Z"},"accession":"S-EPMC12809547","cross_references":{"pubmed":["41552523"],"doi":["10.1021/acsomega.5c07873"]}}