{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Sollis KA"],"funding":["World Health Organization","NIAID NIH HHS"],"pagination":["e85869"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC3928047"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["9(2)"],"pubmed_abstract":["<h4>Background</h4>Viral load (VL) monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring.<h4>Methods and findings</h4>A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25), Cobas TaqMan v2.0 (n = 11), Abbott RealTime HIV-1 (n = 23), Versant HIV-1 RNA bDNA 3.0 (n = 15), Versant HIV-1 RNA kPCR 1.0 (n = 2), ExaVir Load v3 (n = 2"],"journal":["PloS one"],"pubmed_title":["Systematic review of the performance of HIV viral load technologies on plasma samples."],"pmcid":["PMC3928047"],"funding_grant_id":["P30 AI050410","001"],"pubmed_authors":["Smit PW","Perrins J","Fiscus S","Stevens W","Vitoria M","Cheng B","Peeling RW","Sollis KA","Ford N","Denny T","Essajee S","Crowe SM","Habiyambere V","Barnett D","Landay A"],"additional_accession":[]},"is_claimable":false,"name":"Systematic review of the performance of HIV viral load technologies on plasma samples.","description":"<h4>Background</h4>Viral load (VL) monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring.<h4>Methods and findings</h4>A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25), Cobas TaqMan v2.0 (n = 11), Abbott RealTime HIV-1 (n = 23), Versant HIV-1 RNA bDNA 3.0 (n = 15), Versant HIV-1 RNA kPCR 1.0 (n = 2), ExaVir Load v3 (n = 2","dates":{"release":"2014-01-01T00:00:00Z","publication":"2014","modification":"2025-04-04T19:08:52.084Z","creation":"2019-03-26T23:23:43Z"},"accession":"S-EPMC3928047","cross_references":{"pubmed":["24558359"],"doi":["10.1371/journal.pone.0085869"]}}