{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["21(Pt 5)"],"submitter":["Johansson M"],"pubmed_abstract":["The MAX IV 3 GeV storage ring, currently under construction, pursues the goal of low electron beam emittance by using a multi-bend achromat magnet lattice, which is realised by having several consecutive magnet elements precision-machined out of a common solid iron block, 2.3-3.4 m long. With this magnet design solution, instead of having 1320 individual magnets, the MAX IV 3 GeV storage ring is built up using 140 integrated `magnet block' units, containing all these magnet elements. Major features of this magnet block design are compactness, vibration stability and that the alignment of magnet elements within each unit is given by the mechanical accuracy of the CNC machining rather than individual field measurement and adjustment. This article presents practical engineering details of imp"],"journal":["Journal of synchrotron radiation"],"pagination":["884-903"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC4181640"],"repository":["biostudies-literature"],"pubmed_title":["Magnet design for a low-emittance storage ring."],"pmcid":["PMC4181640"],"pubmed_authors":["Anderberg B","Johansson M","Lindgren LJ"],"additional_accession":[]},"is_claimable":false,"name":"Magnet design for a low-emittance storage ring.","description":"The MAX IV 3 GeV storage ring, currently under construction, pursues the goal of low electron beam emittance by using a multi-bend achromat magnet lattice, which is realised by having several consecutive magnet elements precision-machined out of a common solid iron block, 2.3-3.4 m long. With this magnet design solution, instead of having 1320 individual magnets, the MAX IV 3 GeV storage ring is built up using 140 integrated `magnet block' units, containing all these magnet elements. Major features of this magnet block design are compactness, vibration stability and that the alignment of magnet elements within each unit is given by the mechanical accuracy of the CNC machining rather than individual field measurement and adjustment. This article presents practical engineering details of imp","dates":{"release":"2014-01-01T00:00:00Z","publication":"2014 Sep","modification":"2026-04-16T14:01:00.087Z","creation":"2026-04-07T14:13:10.038Z"},"accession":"S-EPMC4181640","cross_references":{"pubmed":["25177980"],"doi":["10.1107/S160057751401666X"]}}