<HashMap><database>biostudies-literature</database><scores/><additional><submitter>Wagner F</submitter><funding>Deutsche Forschungsgemeinschaft</funding><pagination>e0179276</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC5476261</full_dataset_link><repository>biostudies-literature</repository><omics_type>Unknown</omics_type><volume>12(6)</volume><pubmed_abstract>To use the "apparent diffusion coefficient" (Dapp) as a quantitative imaging parameter, well-suited test fluids are essential. In this study, the previously proposed aqueous solutions of polyvinylpyrrolidone (PVP) were examined and temperature calibrations were obtained. For example, at a temperature of 20°C, Dapp ranged from 1.594 (95% CI: 1.593, 1.595) μm2/ms to 0.3326 (95% CI: 0. 3304, 0.3348) μm2/ms for PVP-concentrations ranging from 10% (w/w) to 50% (w/w) using K30 polymer lengths. The temperature dependence of Dapp was found to be so strong that a negligence seems not advisable. The temperature dependence is descriptively modelled by an exponential function exp(c2 (T - 20°C)) and the determined c2 values are reported, which can be used for temperature calibration. For example, we fi</pubmed_abstract><journal>PloS one</journal><pubmed_title>Temperature and concentration calibration of aqueous polyvinylpyrrolidone (PVP) solutions for isotropic diffusion MRI phantoms.</pubmed_title><pmcid>PMC5476261</pmcid><funding_grant_id>LA 2804/1-3</funding_grant_id><pubmed_authors>Faust J</pubmed_authors><pubmed_authors>Demberg K</pubmed_authors><pubmed_authors>Wagner F</pubmed_authors><pubmed_authors>Bickelhaupt S</pubmed_authors><pubmed_authors>Maier-Hein K</pubmed_authors><pubmed_authors>Laun FB</pubmed_authors><pubmed_authors>Rivkin B</pubmed_authors><pubmed_authors>Nagel AM</pubmed_authors><pubmed_authors>Ladd ME</pubmed_authors><pubmed_authors>Mlynarska A</pubmed_authors><pubmed_authors>Lindemann L</pubmed_authors><pubmed_authors>Bach M</pubmed_authors><pubmed_authors>Maier F</pubmed_authors><pubmed_authors>Kuder TA</pubmed_authors></additional><is_claimable>false</is_claimable><name>Temperature and concentration calibration of aqueous polyvinylpyrrolidone (PVP) solutions for isotropic diffusion MRI phantoms.</name><description>To use the "apparent diffusion coefficient" (Dapp) as a quantitative imaging parameter, well-suited test fluids are essential. In this study, the previously proposed aqueous solutions of polyvinylpyrrolidone (PVP) were examined and temperature calibrations were obtained. For example, at a temperature of 20°C, Dapp ranged from 1.594 (95% CI: 1.593, 1.595) μm2/ms to 0.3326 (95% CI: 0. 3304, 0.3348) μm2/ms for PVP-concentrations ranging from 10% (w/w) to 50% (w/w) using K30 polymer lengths. The temperature dependence of Dapp was found to be so strong that a negligence seems not advisable. The temperature dependence is descriptively modelled by an exponential function exp(c2 (T - 20°C)) and the determined c2 values are reported, which can be used for temperature calibration. For example, we fi</description><dates><release>2017-01-01T00:00:00Z</release><publication>2017</publication><modification>2025-04-18T13:23:28.669Z</modification><creation>2019-03-27T02:47:56Z</creation></dates><accession>S-EPMC5476261</accession><cross_references><pubmed>28628638</pubmed><doi>10.1371/journal.pone.0179276</doi></cross_references></HashMap>