{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Fagnant CS"],"funding":["Paul G. Allen Family Foundation (US)"],"pagination":["574"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC5648745"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["189(11)"],"pubmed_abstract":["Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device desc"],"journal":["Environmental monitoring and assessment"],"pubmed_title":["Development of an elution device for ViroCap virus filters."],"pmcid":["PMC5648745"],"funding_grant_id":["NPT.1938-603689"],"pubmed_authors":["Shirai JH","Boyle DS","Guan Y","Ockerman B","Novosselov I","Powell J","Zhou NA","Fagnant CS","Toles M","Adolphsen J","Meschke JS"],"additional_accession":[]},"is_claimable":false,"name":"Development of an elution device for ViroCap virus filters.","description":"Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device desc","dates":{"release":"2017-01-01T00:00:00Z","publication":"2017 Oct","modification":"2025-05-29T22:07:33.859Z","creation":"2025-05-29T22:07:33.859Z"},"accession":"S-EPMC5648745","cross_references":{"pubmed":["29046968"],"doi":["10.1007/s10661-017-6258-y"]}}