<HashMap><database>biostudies-literature</database><scores/><additional><omics_type>Unknown</omics_type><volume>18(9)</volume><submitter>Webster LR</submitter><pubmed_abstract>&lt;h4>Objective&lt;/h4>To compare the relative human abuse potential after insufflation of manipulated morphine abuse-deterrent, extended-release injection-molded tablets (morphine-ADER-IMT) with that of marketed morphine ER tablets.&lt;h4>Methods&lt;/h4>A randomized, double-blind, double-dummy, active- and placebo-controlled five-way crossover study was performed with adult volunteers who were experienced, nondependent, recreational opioid users. After intranasal (IN) administration of manipulated high-volume (HV) morphine-ADER-IMT (60 mg), participants were randomized (1:1:1:1) to receive IN manipulated low-volume (LV) morphine ER (60 mg), IN manipulated LV morphine-ADER-IMT, intact oral morphine-ADER-IMT (60 mg), and placebo in crossover fashion. Pharmacodynamic and pharmacokinetic assessments inc</pubmed_abstract><journal>Pain medicine (Malden, Mass.)</journal><pagination>1695-1705</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC5939830</full_dataset_link><repository>biostudies-literature</repository><pubmed_title>Human Abuse Potential of an Abuse-Deterrent (AD), Extended-Release (ER) Morphine Product Candidate (Morphine-ADER Injection-Molded Tablets) vs Extended-Release Morphine Administered Intranasally in Nondependent Recreational Opioid Users.</pubmed_title><pmcid>PMC5939830</pmcid><pubmed_authors>Dayno JM</pubmed_authors><pubmed_authors>Lindhardt K</pubmed_authors><pubmed_authors>Lawler J</pubmed_authors><pubmed_authors>Smith MD</pubmed_authors><pubmed_authors>Webster LR</pubmed_authors></additional><is_claimable>false</is_claimable><name>Human Abuse Potential of an Abuse-Deterrent (AD), Extended-Release (ER) Morphine Product Candidate (Morphine-ADER Injection-Molded Tablets) vs Extended-Release Morphine Administered Intranasally in Nondependent Recreational Opioid Users.</name><description>&lt;h4>Objective&lt;/h4>To compare the relative human abuse potential after insufflation of manipulated morphine abuse-deterrent, extended-release injection-molded tablets (morphine-ADER-IMT) with that of marketed morphine ER tablets.&lt;h4>Methods&lt;/h4>A randomized, double-blind, double-dummy, active- and placebo-controlled five-way crossover study was performed with adult volunteers who were experienced, nondependent, recreational opioid users. After intranasal (IN) administration of manipulated high-volume (HV) morphine-ADER-IMT (60 mg), participants were randomized (1:1:1:1) to receive IN manipulated low-volume (LV) morphine ER (60 mg), IN manipulated LV morphine-ADER-IMT, intact oral morphine-ADER-IMT (60 mg), and placebo in crossover fashion. Pharmacodynamic and pharmacokinetic assessments inc</description><dates><release>2017-01-01T00:00:00Z</release><publication>2017 Sep</publication><modification>2025-04-22T01:39:42.85Z</modification><creation>2019-03-26T23:37:13Z</creation></dates><accession>S-EPMC5939830</accession><cross_references><pubmed>27651510</pubmed><doi>10.1093/pm/pnw219</doi></cross_references></HashMap>