{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["8(7)"],"submitter":["Aldalbahi A"],"pubmed_abstract":["Acid-functionalized single-walled carbon nanotube (a-SWCNT)-coated reticulated vitreous carbon (RVC) composite electrodes have been prepared and the use of these electrodes in capacitive deionization (CDI) cells for water desalination has been the focus of this study. The performance of these electrodes was tested based on the applied voltage, flow rate, bias potential and a-SWCNT loadings, and then evaluated by electrosorption dynamics. The effect of the feed stream directly through the electrodes, between the electrodes, and the distance between the electrodes in the CDI system on the performance of the electrodes has been investigated. The interaction of ions with the electrodes was tested through Langmuir and Freundlich isotherm models. A new CDI cell was developed, which shows an incr"],"journal":["Nanomaterials (Basel, Switzerland)"],"pagination":["E527"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC6071079"],"repository":["biostudies-literature"],"pubmed_title":["Single-Walled Carbon Nanotube (SWCNT) Loaded Porous Reticulated Vitreous Carbon (RVC) Electrodes Used in a Capacitive Deionization (CDI) Cell for Effective Desalination."],"pmcid":["PMC6071079"],"pubmed_authors":["Alrehaili A","Rahaman M","Aldalbahi A","Almoiqli M","Hamedelniel A"],"additional_accession":[]},"is_claimable":false,"name":"Single-Walled Carbon Nanotube (SWCNT) Loaded Porous Reticulated Vitreous Carbon (RVC) Electrodes Used in a Capacitive Deionization (CDI) Cell for Effective Desalination.","description":"Acid-functionalized single-walled carbon nanotube (a-SWCNT)-coated reticulated vitreous carbon (RVC) composite electrodes have been prepared and the use of these electrodes in capacitive deionization (CDI) cells for water desalination has been the focus of this study. The performance of these electrodes was tested based on the applied voltage, flow rate, bias potential and a-SWCNT loadings, and then evaluated by electrosorption dynamics. The effect of the feed stream directly through the electrodes, between the electrodes, and the distance between the electrodes in the CDI system on the performance of the electrodes has been investigated. The interaction of ions with the electrodes was tested through Langmuir and Freundlich isotherm models. A new CDI cell was developed, which shows an incr","dates":{"release":"2018-01-01T00:00:00Z","publication":"2018 Jul","modification":"2025-04-19T20:56:22.248Z","creation":"2019-03-26T23:50:27Z"},"accession":"S-EPMC6071079","cross_references":{"pubmed":["30011849"],"doi":["10.3390/nano8070527"]}}