{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"submitter":["Cheung CSN"],"pubmed_abstract":["We report detailed procedures for performing compression experiments on rocks and mineral aggregates within a multi-anvil deformation apparatus (D-DIA) coupled with synchrotron X-radiation. A cube-shaped sample assembly is prepared and compressed, at room temperature, by a set of four X-ray transparent sintered diamond anvils and two tungsten carbide anvils, in the lateral and the vertical planes, respectively. All six anvils are housed within a 250-ton hydraulic press and driven inward simultaneously by two wedged guide blocks. A horizontal energy dispersive X-ray beam is projected through and diffracted by the sample assembly. The beam is commonly in the mode of either white or monochromatic X-ray. In the case of white X-ray, the diffracted X-rays are detected by a solid-state detector a"],"journal":["Journal of visualized experiments : JoVE"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC6101276"],"repository":["biostudies-literature"],"pubmed_title":["Stress Distribution During Cold Compression of Rocks and Mineral Aggregates Using Synchrotron-based X-Ray Diffraction."],"pmcid":["PMC6101276"],"pubmed_authors":["Meredith PG","Cheung CSN","Whitaker M","Chen H","Chen X","Weidner DJ","Li L"],"additional_accession":[]},"is_claimable":false,"name":"Stress Distribution During Cold Compression of Rocks and Mineral Aggregates Using Synchrotron-based X-Ray Diffraction.","description":"We report detailed procedures for performing compression experiments on rocks and mineral aggregates within a multi-anvil deformation apparatus (D-DIA) coupled with synchrotron X-radiation. A cube-shaped sample assembly is prepared and compressed, at room temperature, by a set of four X-ray transparent sintered diamond anvils and two tungsten carbide anvils, in the lateral and the vertical planes, respectively. All six anvils are housed within a 250-ton hydraulic press and driven inward simultaneously by two wedged guide blocks. A horizontal energy dispersive X-ray beam is projected through and diffracted by the sample assembly. The beam is commonly in the mode of either white or monochromatic X-ray. In the case of white X-ray, the diffracted X-rays are detected by a solid-state detector a","dates":{"release":"2018-01-01T00:00:00Z","publication":"2018 May","modification":"2026-06-14T03:25:58.014Z","creation":"2026-06-14T03:16:10.942Z"},"accession":"S-EPMC6101276","cross_references":{"pubmed":["29863676"],"doi":["10.3791/57555"]}}