{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Tran-Lam TT"],"funding":["VAST.TĐ.TP/16-18"],"pagination":["E69"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC6316763"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["6(4)"],"pubmed_abstract":["A novel method was developed for the sensitive, cheap and fast quantitation of 10 phthalates in non-alcoholic beverages by liquid⁻liquid extraction (LLE) combined with gas chromatography tandem mass spectrometry (GC-MS/MS). The best results were obtained when <i>n</i>-hexane was used as extraction solvent. A central composite design (CCD) was applied to select the most appreciated operating condition. The method performance was evaluated according to the SANTE/11945/2015 guidelines and was linear in the 0.1 to 200 µg/L range for 10 phthalate compounds, with <i>r</i>² > 0.996 and individual residuals <15%. Repeatability (RSD<sub>r</sub>), within-laboratory reproducibility (RSD<sub>wr</sub>), and the trueness range were from 2.7 to 9.1%, from 3.4 to 14.3% and from 91.5 to 118.1%, respectivel"],"journal":["Toxics"],"pubmed_title":["Optimization of Sample Preparation for Detection of 10 Phthalates in Non-Alcoholic Beverages in Northern Vietnam."],"pmcid":["PMC6316763"],"funding_grant_id":["VAST.TĐ.TP.03/16-18"],"pubmed_authors":["Nguyen DT","Ma HK","Le GT","Tran-Lam TT","Pham TQ","Dao YH"],"additional_accession":[]},"is_claimable":false,"name":"Optimization of Sample Preparation for Detection of 10 Phthalates in Non-Alcoholic Beverages in Northern Vietnam.","description":"A novel method was developed for the sensitive, cheap and fast quantitation of 10 phthalates in non-alcoholic beverages by liquid⁻liquid extraction (LLE) combined with gas chromatography tandem mass spectrometry (GC-MS/MS). The best results were obtained when <i>n</i>-hexane was used as extraction solvent. A central composite design (CCD) was applied to select the most appreciated operating condition. The method performance was evaluated according to the SANTE/11945/2015 guidelines and was linear in the 0.1 to 200 µg/L range for 10 phthalate compounds, with <i>r</i>² > 0.996 and individual residuals <15%. Repeatability (RSD<sub>r</sub>), within-laboratory reproducibility (RSD<sub>wr</sub>), and the trueness range were from 2.7 to 9.1%, from 3.4 to 14.3% and from 91.5 to 118.1%, respectivel","dates":{"release":"2018-01-01T00:00:00Z","publication":"2018 Nov","modification":"2026-07-16T16:37:14.153Z","creation":"2019-03-26T22:36:08Z"},"accession":"S-EPMC6316763","cross_references":{"pubmed":["30463241"],"doi":["10.3390/toxics6040069"]}}