{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["15(3)"],"submitter":["Lee W"],"pubmed_abstract":["AIM:This study was conducted to investigate the effect of resuscitation guideline terminology on the performance of infant cardiopulmonary resuscitation (CPR). METHODS:A total of 40 intern or resident physicians conducted 2-min CPR with the two-finger technique (TFT) and two-thumb technique (TT) on a simulated infant cardiac arrest model with a 1-day interval. They were randomly assigned to Group A or B. The participants of Group A conducted CPR with the chest compression depth (CCD) target of \"approximately 4 cm\" and those of Group B conducted CPR with the CCD target of \"at least one-third the anterior-posterior diameter of the chest\". Single rescuer CPR was performed with a 15:2 compression to ventilation ratio on the floor. RESULTS:In both chest compression techniques, the average CCD o"],"journal":["PloS one"],"pagination":["e0230687"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC7092967"],"repository":["biostudies-literature"],"pubmed_title":["Differences in the performance of resuscitation according to the resuscitation guideline terminology during infant cardiopulmonary resuscitation: \"Approximately 4 cm\" versus \"at least one-third the anterior-posterior diameter of the chest\"."],"pmcid":["PMC7092967"],"pubmed_authors":["Yang D","Oh JH","Lee W"],"additional_accession":[]},"is_claimable":false,"name":"Differences in the performance of resuscitation according to the resuscitation guideline terminology during infant cardiopulmonary resuscitation: \"Approximately 4 cm\" versus \"at least one-third the anterior-posterior diameter of the chest\".","description":"AIM:This study was conducted to investigate the effect of resuscitation guideline terminology on the performance of infant cardiopulmonary resuscitation (CPR). METHODS:A total of 40 intern or resident physicians conducted 2-min CPR with the two-finger technique (TFT) and two-thumb technique (TT) on a simulated infant cardiac arrest model with a 1-day interval. They were randomly assigned to Group A or B. The participants of Group A conducted CPR with the chest compression depth (CCD) target of \"approximately 4 cm\" and those of Group B conducted CPR with the CCD target of \"at least one-third the anterior-posterior diameter of the chest\". Single rescuer CPR was performed with a 15:2 compression to ventilation ratio on the floor. RESULTS:In both chest compression techniques, the average CCD o","dates":{"release":"2020-01-01T00:00:00Z","publication":"2020","modification":"2025-04-18T21:12:26.428Z","creation":"2020-05-22T15:15:57Z"},"accession":"S-EPMC7092967","cross_references":{"pubmed":["32208443"],"doi":["10.1371/journal.pone.0230687"]}}