<HashMap><database>biostudies-literature</database><scores/><additional><omics_type>Unknown</omics_type><volume>37(9)</volume><submitter>van Rooij WJ</submitter><pubmed_abstract>&lt;h4>Background and purpose&lt;/h4>The Woven EndoBridge (WEB) device was recently introduced for intrasaccular treatment of wide-neck aneurysms without the need for adjunctive support. We present our first experience in using the WEB for small ruptured aneurysms.&lt;h4>Materials and methods&lt;/h4>During 11 months, 32 of 71 (45%) endovascularly treated acutely ruptured aneurysms were treated with the WEB. The patients were 12 men and 20 women, with a mean age of 61 years (range, 34-84 years). The mean aneurysm size was 4.9 mm, and 14 were ≤4 mm. Of 32 aneurysms, 24 (75%) had a wide neck.&lt;h4>Results&lt;/h4>All 32 aneurysms were adequately occluded after WEB placement. There were no procedural ruptures and no complications related to the WEB device. No adjunctive stents or balloons were needed. In 3 pati</pubmed_abstract><journal>AJNR. American journal of neuroradiology</journal><pagination>1679-83</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC7984684</full_dataset_link><repository>biostudies-literature</repository><pubmed_title>WEB Treatment of Ruptured Intracranial Aneurysms.</pubmed_title><pmcid>PMC7984684</pmcid><pubmed_authors>van Rooij WJ</pubmed_authors><pubmed_authors>Peluso JP</pubmed_authors><pubmed_authors>Bechan RS</pubmed_authors><pubmed_authors>Sluzewski M</pubmed_authors></additional><is_claimable>false</is_claimable><name>WEB Treatment of Ruptured Intracranial Aneurysms.</name><description>&lt;h4>Background and purpose&lt;/h4>The Woven EndoBridge (WEB) device was recently introduced for intrasaccular treatment of wide-neck aneurysms without the need for adjunctive support. We present our first experience in using the WEB for small ruptured aneurysms.&lt;h4>Materials and methods&lt;/h4>During 11 months, 32 of 71 (45%) endovascularly treated acutely ruptured aneurysms were treated with the WEB. The patients were 12 men and 20 women, with a mean age of 61 years (range, 34-84 years). The mean aneurysm size was 4.9 mm, and 14 were ≤4 mm. Of 32 aneurysms, 24 (75%) had a wide neck.&lt;h4>Results&lt;/h4>All 32 aneurysms were adequately occluded after WEB placement. There were no procedural ruptures and no complications related to the WEB device. No adjunctive stents or balloons were needed. In 3 pati</description><dates><release>2016-01-01T00:00:00Z</release><publication>2016 Sep</publication><modification>2025-04-04T22:00:57.58Z</modification><creation>2025-04-04T22:00:57.58Z</creation></dates><accession>S-EPMC7984684</accession><cross_references><pubmed>27102307</pubmed><doi>10.3174/ajnr.A4811</doi><doi>10.3174/ajnr.a4811</doi></cross_references></HashMap>