{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["23(1)"],"submitter":["Nussbaumer C"],"pubmed_abstract":["<h4>Background</h4>Cardiovascular magnetic resonance (CMR) is considered the method of choice for evaluation of aortic root dilatation in congenital heart disease. Usually, a cross-sectional 2D cine stack is acquired perpendicular to the vessel's axis. However, this method requires a considerable patient collaboration and precise planning of image planes. The present study compares a recently introduced 3D self-navigated free-breathing high-resolution whole heart CMR sequence (3D self nav) allowing a multiplanar retrospective reconstruction of the aortic root as an alternative to the 2D cine technique for determination of aortic root diameters.<h4>Methods</h4>A total of 6 cusp-commissure (CuCo) and cusp-cusp (CuCu) enddiastolic diameters were measured by two observers on 2D cine and 3D sel"],"journal":["Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance"],"pagination":["65"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC8157643"],"repository":["biostudies-literature"],"pubmed_title":["2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease."],"pmcid":["PMC8157643"],"pubmed_authors":["Bouchardy J","Blanche C","Nussbaumer C","Pavon AG","Monney P","Stuber M","Schwitter J","Rutz T","Piccini D"],"additional_accession":[]},"is_claimable":false,"name":"2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease.","description":"<h4>Background</h4>Cardiovascular magnetic resonance (CMR) is considered the method of choice for evaluation of aortic root dilatation in congenital heart disease. Usually, a cross-sectional 2D cine stack is acquired perpendicular to the vessel's axis. However, this method requires a considerable patient collaboration and precise planning of image planes. The present study compares a recently introduced 3D self-navigated free-breathing high-resolution whole heart CMR sequence (3D self nav) allowing a multiplanar retrospective reconstruction of the aortic root as an alternative to the 2D cine technique for determination of aortic root diameters.<h4>Methods</h4>A total of 6 cusp-commissure (CuCo) and cusp-cusp (CuCu) enddiastolic diameters were measured by two observers on 2D cine and 3D sel","dates":{"release":"2021-01-01T00:00:00Z","publication":"2021 May","modification":"2025-04-04T10:18:10.117Z","creation":"2025-04-04T10:18:10.117Z"},"accession":"S-EPMC8157643","cross_references":{"pubmed":["34039356"],"doi":["10.1186/s12968-021-00744-1"]}}