<HashMap><database>biostudies-literature</database><scores/><additional><omics_type>Unknown</omics_type><volume>3(6)</volume><submitter>Ito J</submitter><pubmed_abstract>&lt;h4>Objectives&lt;/h4>We conducted a pilot study using an experimental study protocol to evaluate the measurement error of arterial pulse contour analysis-derived stroke volume due to improper transducer leveling during the passive leg raising test and the impact of such error on the determination of fluid responsiveness.&lt;h4>Design&lt;/h4>Prospective observational study.&lt;h4>Setting&lt;/h4>A medical-surgical ICU at a tertiary referral center in Kobe, Japan.&lt;h4>Patients&lt;/h4>Consecutive critically ill adult patients using the FloTrac system Version 4.0 (Edwards Lifesciences, Irvine, CA) for hemodynamic monitoring between September 1, 2018, and November 31, 2018.&lt;h4>Interventions&lt;/h4>None.&lt;h4>Measurements and main results&lt;/h4>Using 20 patients, we estimated the change in the zero-reference level of an </pubmed_abstract><journal>Critical care explorations</journal><pagination>e0465</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC8208422</full_dataset_link><repository>biostudies-literature</repository><pubmed_title>The Effect of Changing Arterial Transducer Position on Stroke Volume Measurements Using FloTrac System Version 4.0: A Pilot Experimental Study.</pubmed_title><pmcid>PMC8208422</pmcid><pubmed_authors>Morimoto T</pubmed_authors><pubmed_authors>Shimozono T</pubmed_authors><pubmed_authors>Ueta H</pubmed_authors><pubmed_authors>Ito J</pubmed_authors><pubmed_authors>Mima H</pubmed_authors><pubmed_authors>Kawakami D</pubmed_authors></additional><is_claimable>false</is_claimable><name>The Effect of Changing Arterial Transducer Position on Stroke Volume Measurements Using FloTrac System Version 4.0: A Pilot Experimental Study.</name><description>&lt;h4>Objectives&lt;/h4>We conducted a pilot study using an experimental study protocol to evaluate the measurement error of arterial pulse contour analysis-derived stroke volume due to improper transducer leveling during the passive leg raising test and the impact of such error on the determination of fluid responsiveness.&lt;h4>Design&lt;/h4>Prospective observational study.&lt;h4>Setting&lt;/h4>A medical-surgical ICU at a tertiary referral center in Kobe, Japan.&lt;h4>Patients&lt;/h4>Consecutive critically ill adult patients using the FloTrac system Version 4.0 (Edwards Lifesciences, Irvine, CA) for hemodynamic monitoring between September 1, 2018, and November 31, 2018.&lt;h4>Interventions&lt;/h4>None.&lt;h4>Measurements and main results&lt;/h4>Using 20 patients, we estimated the change in the zero-reference level of an </description><dates><release>2021-01-01T00:00:00Z</release><publication>2021 Jun</publication><modification>2025-04-04T09:30:03.428Z</modification><creation>2022-02-10T16:00:51.641Z</creation></dates><accession>S-EPMC8208422</accession><cross_references><pubmed>34151286</pubmed><doi>10.1097/CCE.0000000000000465</doi></cross_references></HashMap>