{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["9(16)"],"submitter":["Jiang X"],"pubmed_abstract":["<h4>Background</h4>The diagnosis of burn depth often relies on the subjective judgment of plastic surgeons. Contrast-enhanced ultrasound (CEUS) can visualize the microcirculation well and has potential value in diagnosing the depth of burn wounds. We assessed the depth of the burn wounds by CEUS, and compared the results with histological examination.<h4>Methods</h4>Two rhesus monkeys were used, and multiple burn wounds with different depths were made on their backs. The echo of the dermis and subcutaneous tissue were observed for each wound, and the thickness of the dermis was measured. CEUS was performed to evaluate the depth of burn wounds and compared with pathological results.<h4>Results</h4>(I) After scalding, dermal tissue edema occurred, and the thickness of the dermis measured by "],"journal":["Annals of translational medicine"],"pagination":["1315"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC8422095"],"repository":["biostudies-literature"],"pubmed_title":["Application of contrast-enhanced ultrasound in the diagnosis of burn depth."],"pmcid":["PMC8422095"],"pubmed_authors":["Li G","Ye Q","Jiang X","Li F","Luo Y","Chen X","Chi Y","Song W"],"additional_accession":[]},"is_claimable":false,"name":"Application of contrast-enhanced ultrasound in the diagnosis of burn depth.","description":"<h4>Background</h4>The diagnosis of burn depth often relies on the subjective judgment of plastic surgeons. Contrast-enhanced ultrasound (CEUS) can visualize the microcirculation well and has potential value in diagnosing the depth of burn wounds. We assessed the depth of the burn wounds by CEUS, and compared the results with histological examination.<h4>Methods</h4>Two rhesus monkeys were used, and multiple burn wounds with different depths were made on their backs. The echo of the dermis and subcutaneous tissue were observed for each wound, and the thickness of the dermis was measured. CEUS was performed to evaluate the depth of burn wounds and compared with pathological results.<h4>Results</h4>(I) After scalding, dermal tissue edema occurred, and the thickness of the dermis measured by ","dates":{"release":"2021-01-01T00:00:00Z","publication":"2021 Aug","modification":"2025-04-22T21:15:50.128Z","creation":"2025-04-06T03:29:29.909Z"},"accession":"S-EPMC8422095","cross_references":{"pubmed":["34532452"],"doi":["10.21037/atm-21-3715"]}}