<HashMap><database>biostudies-literature</database><scores/><additional><submitter>Nye JA</submitter><funding>NHLBI NIH HHS</funding><pagination>5072-5084</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC8455441</full_dataset_link><repository>biostudies-literature</repository><omics_type>Unknown</omics_type><volume>48(9)</volume><pubmed_abstract>This work expands on the implementation of three-dimensional (3D) normalized gradient fields to correct for whole-body motion and cardiac creep in [N-13]-ammonia patient studies and evaluates its accuracy using a dynamic phantom simulation model.&lt;h4>Methods&lt;/h4>A full rigid-body algorithm was developed using 3D normalized gradient fields including a multi-resolution step and sampling off the voxel grid to reduce interpolation artifacts. Optimization was performed using a weighted similarity metric that accounts for opposing gradients between images of blood pool and perfused tissue without the need for segmentation. Forty-three retrospective dynamic [N-13]-ammonia PET/CT rest/adenosine-stress patient studies were motion corrected and the mean motion parameters plotted at each frame time po</pubmed_abstract><journal>Medical physics</journal><pubmed_title>Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations.</pubmed_title><pmcid>PMC8455441</pmcid><funding_grant_id>R01 HL143350</funding_grant_id><pubmed_authors>Hwang D</pubmed_authors><pubmed_authors>Koo BK</pubmed_authors><pubmed_authors>David Cooke C</pubmed_authors><pubmed_authors>Bom HS</pubmed_authors><pubmed_authors>Garcia EV</pubmed_authors><pubmed_authors>Piccinelli M</pubmed_authors><pubmed_authors>Lee JM</pubmed_authors><pubmed_authors>Cho SG</pubmed_authors><pubmed_authors>Nye JA</pubmed_authors><pubmed_authors>Paeng JC</pubmed_authors><pubmed_authors>Folks R</pubmed_authors></additional><is_claimable>false</is_claimable><name>Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations.</name><description>This work expands on the implementation of three-dimensional (3D) normalized gradient fields to correct for whole-body motion and cardiac creep in [N-13]-ammonia patient studies and evaluates its accuracy using a dynamic phantom simulation model.&lt;h4>Methods&lt;/h4>A full rigid-body algorithm was developed using 3D normalized gradient fields including a multi-resolution step and sampling off the voxel grid to reduce interpolation artifacts. Optimization was performed using a weighted similarity metric that accounts for opposing gradients between images of blood pool and perfused tissue without the need for segmentation. Forty-three retrospective dynamic [N-13]-ammonia PET/CT rest/adenosine-stress patient studies were motion corrected and the mean motion parameters plotted at each frame time po</description><dates><release>2021-01-01T00:00:00Z</release><publication>2021 Sep</publication><modification>2025-04-19T01:36:15.776Z</modification><creation>2025-04-07T12:18:10.019Z</creation></dates><accession>S-EPMC8455441</accession><cross_references><pubmed>34174095</pubmed><doi>10.1002/mp.15059</doi></cross_references></HashMap>