{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Byun HK"],"funding":["National Research Foundation of Korea"],"pagination":["203"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC8518257"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["16(1)"],"pubmed_abstract":["<h4>Purpose</h4>To study the performance of a proposed deep learning-based autocontouring system in delineating organs at risk (OARs) in breast radiotherapy with a group of experts.<h4>Methods</h4>Eleven experts from two institutions delineated nine OARs in 10 cases of adjuvant radiotherapy after breast-conserving surgery. Autocontours were then provided to the experts for correction. Overall, 110 manual contours, 110 corrected autocontours, and 10 autocontours of each type of OAR were analyzed. The Dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to compare the degree of agreement between the best manual contour (chosen by an independent expert committee) and each autocontour, corrected autocontour, and manual contour. Higher DSCs and lower HDs indicated a better ge"],"journal":["Radiation oncology (London, England)"],"pubmed_title":["Evaluation of deep learning-based autosegmentation in breast cancer radiotherapy."],"pmcid":["PMC8518257"],"funding_grant_id":["2019R1C1C1009359"],"pubmed_authors":["Lee S","Choi MS","Jung J","Jeong C","Chung SY","Byun HK","Chun J","Chang Y","Chang JS","Kim JS","Kim YB"],"additional_accession":[]},"is_claimable":false,"name":"Evaluation of deep learning-based autosegmentation in breast cancer radiotherapy.","description":"<h4>Purpose</h4>To study the performance of a proposed deep learning-based autocontouring system in delineating organs at risk (OARs) in breast radiotherapy with a group of experts.<h4>Methods</h4>Eleven experts from two institutions delineated nine OARs in 10 cases of adjuvant radiotherapy after breast-conserving surgery. Autocontours were then provided to the experts for correction. Overall, 110 manual contours, 110 corrected autocontours, and 10 autocontours of each type of OAR were analyzed. The Dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to compare the degree of agreement between the best manual contour (chosen by an independent expert committee) and each autocontour, corrected autocontour, and manual contour. Higher DSCs and lower HDs indicated a better ge","dates":{"release":"2021-01-01T00:00:00Z","publication":"2021 Oct","modification":"2025-04-04T13:17:08.745Z","creation":"2025-04-04T13:17:08.745Z"},"accession":"S-EPMC8518257","cross_references":{"pubmed":["34649569"],"doi":["10.1186/s13014-021-01923-1"]}}