{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Marchetti MA"],"funding":["NCI NIH HHS"],"pagination":["680-683"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC9047749"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["158(6)"],"pubmed_abstract":["<h4>Importance</h4>A neural network-based model (i31-GEP-SLNB) that uses clinicopathologic factors (thickness, mitoses, ulceration, patient age) plus molecular analysis (31-gene expression profiling) has become commercially available to guide selection for sentinel lymph node (SLN) biopsy in cutaneous melanoma, but its clinical utility is not well characterized.<h4>Objective</h4>To determine if use of the i31-GEP-SLNB model is associated with clinical benefit when used to select patients for SLN biopsy.<h4>Design, setting, and participants</h4>This decision-analytic study used data derived from a published external validation study of the i31-GEP-SLNB prediction model. Participants included patients with primary cutaneous melanoma.<h4>Main outcomes and measures</h4>The primary outcome was the net benefit associated with using the i31-GEP-SLNB model for SLN biopsy selection compared with other selection strategies (SLN biopsy for all patients and SLN biopsy for no patients) at a 5% risk threshold. Analyses were stratified by American Joint Committee on Cancer (AJCC) T category. The reduction in the number of avoidable SLN biopsies and relative utility were also calculated.<h4>Results</h4>Compared with other SLN biopsy selection strategies, use of the i31-GEP-SLNB model had greater net benefit for patients with T1b (+0.012), T2a (+0.002), and T2b melanoma (+0.002) but not for those with high-risk T1a (-0.003) disease. The improvement in relative utility was +22% in patients with T1b, +1% in T2a, and +2% in T2b melanoma. Compared with SLN biopsy for all patients, use of the model would equate to a 23% decrease in SLN biopsies among patients with T1b disease without an SLN metastasis with no increase in the number of patients with an SLN metastasis left untreated; among patients with T2a and T2b melanoma, the net decrease in avoidable biopsies compared with SLN biopsy for all was 3% and 4%, respectively.<h4>Conclusions and relevance</h4>The findings of this decision-analytic study suggest that i31-GEP SLNB has significant potential for risk-stratifying patients with T1b melanoma if using a 5% risk threshold; its role among patients with T1a and T2 melanoma or using other risk thresholds requires further study. A prospective validation study confirming the added clinical benefit and cost-effectiveness of i31-GEP-SLNB compared with free clinicopathologic-based prediction models is needed in patients with T1b melanoma."],"journal":["JAMA dermatology"],"pubmed_title":["Utility of a Model for Predicting the Risk of Sentinel Lymph Node Metastasis in Patients With Cutaneous Melanoma."],"pmcid":["PMC9047749"],"funding_grant_id":["P30 CA008748"],"pubmed_authors":["Dusza SW","Bartlett EK","Marchetti MA"],"additional_accession":[]},"is_claimable":false,"name":"Utility of a Model for Predicting the Risk of Sentinel Lymph Node Metastasis in Patients With Cutaneous Melanoma.","description":"<h4>Importance</h4>A neural network-based model (i31-GEP-SLNB) that uses clinicopathologic factors (thickness, mitoses, ulceration, patient age) plus molecular analysis (31-gene expression profiling) has become commercially available to guide selection for sentinel lymph node (SLN) biopsy in cutaneous melanoma, but its clinical utility is not well characterized.<h4>Objective</h4>To determine if use of the i31-GEP-SLNB model is associated with clinical benefit when used to select patients for SLN biopsy.<h4>Design, setting, and participants</h4>This decision-analytic study used data derived from a published external validation study of the i31-GEP-SLNB prediction model. Participants included patients with primary cutaneous melanoma.<h4>Main outcomes and measures</h4>The primary outcome was the net benefit associated with using the i31-GEP-SLNB model for SLN biopsy selection compared with other selection strategies (SLN biopsy for all patients and SLN biopsy for no patients) at a 5% risk threshold. Analyses were stratified by American Joint Committee on Cancer (AJCC) T category. The reduction in the number of avoidable SLN biopsies and relative utility were also calculated.<h4>Results</h4>Compared with other SLN biopsy selection strategies, use of the i31-GEP-SLNB model had greater net benefit for patients with T1b (+0.012), T2a (+0.002), and T2b melanoma (+0.002) but not for those with high-risk T1a (-0.003) disease. The improvement in relative utility was +22% in patients with T1b, +1% in T2a, and +2% in T2b melanoma. Compared with SLN biopsy for all patients, use of the model would equate to a 23% decrease in SLN biopsies among patients with T1b disease without an SLN metastasis with no increase in the number of patients with an SLN metastasis left untreated; among patients with T2a and T2b melanoma, the net decrease in avoidable biopsies compared with SLN biopsy for all was 3% and 4%, respectively.<h4>Conclusions and relevance</h4>The findings of this decision-analytic study suggest that i31-GEP SLNB has significant potential for risk-stratifying patients with T1b melanoma if using a 5% risk threshold; its role among patients with T1a and T2 melanoma or using other risk thresholds requires further study. A prospective validation study confirming the added clinical benefit and cost-effectiveness of i31-GEP-SLNB compared with free clinicopathologic-based prediction models is needed in patients with T1b melanoma.","dates":{"release":"2022-01-01T00:00:00Z","publication":"2022 Jun","modification":"2025-04-26T11:09:09.171Z","creation":"2025-04-06T13:33:41.318Z"},"accession":"S-EPMC9047749","cross_references":{"pubmed":["35475908"],"doi":["10.1001/jamadermatol.2022.0970"]}}