{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Liang L"],"funding":["Natural Science Foundation of Zhejiang Province","National Natural Science Foundation of China","State Key Laboratory of Pollution Control and Resource Reuse"],"pagination":["32671-32677"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC9056616"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["10(54)"],"pubmed_abstract":["The effect of a weak magnetic field (WMF) on the removal of reactive brilliant red X-3B (X-3B) by zero-valent iron (ZVI)/H<sub>2</sub>O<sub>2</sub> was studied. The optimum conditions for the removal of X-3B by the ZVI/H<sub>2</sub>O<sub>2</sub>/WMF system were as follows: pH = 4.0, X-3B was 50 mg L<sup>-1</sup>, H<sub>2</sub>O<sub>2</sub> was 8 mM, and ZVI with particle size of 20 μm was 0.5 g L<sup>-1</sup>. The X-3B decolorization rate could reach 99.41% in 10 minutes. The superposed WMF increased the working pH of ZVI from 3.0 to 4.0. The main part of ZVI/H<sub>2</sub>O<sub>2</sub> removal kinetics of X-3B followed the zero order rate law. In this study, the removal effect of X-3B by pre-magnetization ZVI was not as good as that of real-time magnetization, but it was better than the re"],"journal":["RSC advances"],"pubmed_title":["Removal of reactive brilliant red X-3B by a weak magnetic field enhanced Fenton-like system with zero-valent iron."],"pmcid":["PMC9056616"],"funding_grant_id":["41807468","LY18E080018","PCRRF18021"],"pubmed_authors":["Wang Q","Zhang Y","Wu Q","Liang L","Cheng L","Meng X","Xue Y"],"additional_accession":[]},"is_claimable":false,"name":"Removal of reactive brilliant red X-3B by a weak magnetic field enhanced Fenton-like system with zero-valent iron.","description":"The effect of a weak magnetic field (WMF) on the removal of reactive brilliant red X-3B (X-3B) by zero-valent iron (ZVI)/H<sub>2</sub>O<sub>2</sub> was studied. The optimum conditions for the removal of X-3B by the ZVI/H<sub>2</sub>O<sub>2</sub>/WMF system were as follows: pH = 4.0, X-3B was 50 mg L<sup>-1</sup>, H<sub>2</sub>O<sub>2</sub> was 8 mM, and ZVI with particle size of 20 μm was 0.5 g L<sup>-1</sup>. The X-3B decolorization rate could reach 99.41% in 10 minutes. The superposed WMF increased the working pH of ZVI from 3.0 to 4.0. The main part of ZVI/H<sub>2</sub>O<sub>2</sub> removal kinetics of X-3B followed the zero order rate law. In this study, the removal effect of X-3B by pre-magnetization ZVI was not as good as that of real-time magnetization, but it was better than the re","dates":{"release":"2020-01-01T00:00:00Z","publication":"2020 Sep","modification":"2025-04-26T04:32:17.889Z","creation":"2025-04-26T04:32:17.889Z"},"accession":"S-EPMC9056616","cross_references":{"pubmed":["35516516"],"doi":["10.1039/d0ra03480k"]}}