{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Fang G"],"funding":["Jinan University","National Natural Science Foundation of China"],"pagination":["20306-20313"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC9065501"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["9(35)"],"pubmed_abstract":["Boronic acid provides faster fluorescence response to Fe<sup>3+</sup> compared to other reported sensors, which is critical for continuous dynamic detection. Herein, we reported a novel boronic acid-based sensor 4 that could recognize Fe<sup>3+</sup> ion in real time. After 10 equiv. of Fe<sup>3+</sup> ion (1 mM) was added, the fluorescence of sensor 4 was immediately quenched by 96%. While other ions, including Ba<sup>2+</sup>, Ca<sup>2+</sup>, Cr<sup>2+</sup>, Cd<sup>2+</sup>, Co<sup>2+</sup>, Cs<sup>2+</sup>, Cu<sup>2+</sup>, Fe<sup>2+</sup>, K<sup>+</sup>, Li<sup>+</sup>, Mg<sup>2+</sup>, Mn<sup>2+</sup>, Na<sup>+</sup>, Ni<sup>2+</sup> or Zn<sup>2+</sup>, respectively, did not change the fluorescence significantly. Further tests indicated that the high selectively sensing Fe<sup>3+</s"],"journal":["RSC advances"],"pubmed_title":["A novel boronic acid-based fluorescent sensor for selectively recognizing Fe<sup>3+</sup> ion in real time."],"pmcid":["PMC9065501"],"funding_grant_id":["21801158","JDYY1804"],"pubmed_authors":["Guo M","Wu Z","Fang G","Wang H","Bian Z","Yao Q"],"additional_accession":[]},"is_claimable":false,"name":"A novel boronic acid-based fluorescent sensor for selectively recognizing Fe<sup>3+</sup> ion in real time.","description":"Boronic acid provides faster fluorescence response to Fe<sup>3+</sup> compared to other reported sensors, which is critical for continuous dynamic detection. Herein, we reported a novel boronic acid-based sensor 4 that could recognize Fe<sup>3+</sup> ion in real time. After 10 equiv. of Fe<sup>3+</sup> ion (1 mM) was added, the fluorescence of sensor 4 was immediately quenched by 96%. While other ions, including Ba<sup>2+</sup>, Ca<sup>2+</sup>, Cr<sup>2+</sup>, Cd<sup>2+</sup>, Co<sup>2+</sup>, Cs<sup>2+</sup>, Cu<sup>2+</sup>, Fe<sup>2+</sup>, K<sup>+</sup>, Li<sup>+</sup>, Mg<sup>2+</sup>, Mn<sup>2+</sup>, Na<sup>+</sup>, Ni<sup>2+</sup> or Zn<sup>2+</sup>, respectively, did not change the fluorescence significantly. Further tests indicated that the high selectively sensing Fe<sup>3+</s","dates":{"release":"2019-01-01T00:00:00Z","publication":"2019 Jun","modification":"2025-04-22T07:47:04.496Z","creation":"2025-04-05T22:19:35.222Z"},"accession":"S-EPMC9065501","cross_references":{"pubmed":["35514712"],"doi":["10.1039/c9ra03978c"]}}