{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"submitter":["Das M"],"funding":["Ministry of Science and Technology, Taiwan","Chang Gung Medical Foundation"],"pagination":["13774-13782"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC9074847"],"repository":["biostudies-literature"],"omics_type":["Unknown"],"volume":["12(22)"],"pubmed_abstract":["pH monitoring in clinical assessment is pivotal as pH imbalance significantly influences the physiological and extracellular functions of the human body. Metal oxide based pH sensors, a promising alternative to bulky pH electrodes, mostly require complex fabrication, high-temperature post-deposition treatment, and high expenses that inhibit their practical applicability. So, there is still room to develop a straightforward and cost-effective metal oxide based pH sensor comprising high sensitivity and reliability. In this report, a novel solution-processed and low-temperature annealed (220 °C) mixed-valence (vii/vi) oxide of rhenium (Re <sub><i>x</i></sub> O <sub><i>y</i></sub> ) was applied in an electrolyte-insulator-semiconductor (EIS) structure. The annealing effect on morphological, st"],"journal":["RSC advances"],"pubmed_title":["Excellent physicochemical and sensing characteristics of a Re <sub><i>x</i></sub> O <sub><i>y</i></sub> based pH sensor at low post-deposition annealing temperature."],"pmcid":["PMC9074847"],"funding_grant_id":["BMRPA00","MOST 110-2221-E-182-032","CMRPD2J0092","CMRPD2H0182"],"pubmed_authors":["Chakraborty T","Lei KF","Kao CH","Das M","Lin CY"],"additional_accession":[]},"is_claimable":false,"name":"Excellent physicochemical and sensing characteristics of a Re <sub><i>x</i></sub> O <sub><i>y</i></sub> based pH sensor at low post-deposition annealing temperature.","description":"pH monitoring in clinical assessment is pivotal as pH imbalance significantly influences the physiological and extracellular functions of the human body. Metal oxide based pH sensors, a promising alternative to bulky pH electrodes, mostly require complex fabrication, high-temperature post-deposition treatment, and high expenses that inhibit their practical applicability. So, there is still room to develop a straightforward and cost-effective metal oxide based pH sensor comprising high sensitivity and reliability. In this report, a novel solution-processed and low-temperature annealed (220 °C) mixed-valence (vii/vi) oxide of rhenium (Re <sub><i>x</i></sub> O <sub><i>y</i></sub> ) was applied in an electrolyte-insulator-semiconductor (EIS) structure. The annealing effect on morphological, st","dates":{"release":"2022-01-01T00:00:00Z","publication":"2022 May","modification":"2026-05-10T00:48:57.789Z","creation":"2025-02-19T04:21:25.809Z"},"accession":"S-EPMC9074847","cross_references":{"pubmed":["35530391"],"doi":["10.1039/d2ra01177h"]}}