<HashMap><database>biostudies-literature</database><scores/><additional><omics_type>Unknown</omics_type><volume>69(3)</volume><submitter>Nguyen M</submitter><pubmed_abstract>&lt;h4>Introduction&lt;/h4>Paediatric patients (individuals below 18 years of age) requiring cranial-spinal irradiation (CSI) at our institution are commonly planned and treated using a three isocentre (3-ISO) volumetric modulated arc therapy (VMAT) technique. A modified two isocentre (2-ISO) VMAT technique was investigated with the aim to improve workflow and reduce planning and treatment time.&lt;h4>Methods&lt;/h4>Five CSI paediatric patients previously treated with a 3-ISO VMAT technique were retrospectively replanned using a 2-ISO VMAT technique. The 2-ISO VMAT plans were reviewed and approved by a radiation oncologist (RO) before undergoing patient-specific quality assurance (QA) procedures, performed by a radiation oncology medical physicist (ROMP). Planning target volume (PTV) coverage, organ-a</pubmed_abstract><journal>Journal of medical radiation sciences</journal><pagination>357-366</pagination><full_dataset_link>https://www.ebi.ac.uk/biostudies/studies/S-EPMC9442318</full_dataset_link><repository>biostudies-literature</repository><pubmed_title>Modified volumetric modulated arc therapy technique with reduced planning and treatment time for craniospinal irradiation utilising two isocentres.</pubmed_title><pmcid>PMC9442318</pmcid><pubmed_authors>Sim L</pubmed_authors><pubmed_authors>Pullar A</pubmed_authors><pubmed_authors>Cheuk R</pubmed_authors><pubmed_authors>Gibbs A</pubmed_authors><pubmed_authors>Dang T</pubmed_authors><pubmed_authors>Deegan L</pubmed_authors><pubmed_authors>Hargrave C</pubmed_authors><pubmed_authors>Nguyen M</pubmed_authors><pubmed_authors>Henry K</pubmed_authors><pubmed_authors>Jones S</pubmed_authors></additional><is_claimable>false</is_claimable><name>Modified volumetric modulated arc therapy technique with reduced planning and treatment time for craniospinal irradiation utilising two isocentres.</name><description>&lt;h4>Introduction&lt;/h4>Paediatric patients (individuals below 18 years of age) requiring cranial-spinal irradiation (CSI) at our institution are commonly planned and treated using a three isocentre (3-ISO) volumetric modulated arc therapy (VMAT) technique. A modified two isocentre (2-ISO) VMAT technique was investigated with the aim to improve workflow and reduce planning and treatment time.&lt;h4>Methods&lt;/h4>Five CSI paediatric patients previously treated with a 3-ISO VMAT technique were retrospectively replanned using a 2-ISO VMAT technique. The 2-ISO VMAT plans were reviewed and approved by a radiation oncologist (RO) before undergoing patient-specific quality assurance (QA) procedures, performed by a radiation oncology medical physicist (ROMP). Planning target volume (PTV) coverage, organ-a</description><dates><release>2022-01-01T00:00:00Z</release><publication>2022 Sep</publication><modification>2025-04-20T00:39:25.462Z</modification><creation>2025-04-20T00:39:25.462Z</creation></dates><accession>S-EPMC9442318</accession><cross_references><pubmed>35460199</pubmed><doi>10.1002/jmrs.582</doi></cross_references></HashMap>