{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["92(5)"],"submitter":["Ullman AJ"],"pubmed_abstract":["<h4>Background</h4>Healthcare delivery is reliant on a functional central venous access device (CVAD), but the knowledge surrounding the burden of pediatric CVAD-associated harm is limited.<h4>Methods</h4>A prospective cohort study at a tertiary-referral pediatric hospital in Australia. Children <18 years undergoing insertion of a CVAD were screened from the operating theatre and intensive care unit records, then assessed bi-weekly for up to 3 months. Outcomes were CVAD failure and complications, and associated healthcare costs (cost of complications).<h4>Results</h4>163 patients with 200 CVADs were recruited and followed for 6993 catheter days, with peripherally inserted central catheters most common (n = 119; 60%). CVAD failure occurred in 20% of devices (n = 30; 95% CI: 15-26), at an incidence rate (IR) of 5.72 per 1000 catheter days (95% CI: 4.09-7.78). CVAD complications were evident in 43% of all CVADs (n = 86; 95% CI: 36-50), at a rate of 12.29 per 1000 catheter days (95% CI: 9.84-15.16). CVAD failure costs were A$826 per episode, and A$165,372 per 1000 CVADs. Comparisons between current and recommended practice revealed inconsistent use of ultrasound guidance for insertion, sub-optimal tip-positioning, and appropriate device selection.<h4>Conclusions</h4>CVAD complications and failures represent substantial burdens to children and healthcare. Future efforts need to focus on the inconsistent use of best practices.<h4>Impact</h4>Current surveillance of central venous access device (CVAD) performance is likely under-estimating actual burden on pediatric patients and the healthcare system. CVAD failure due to complication was evident in 20% of CVADs. Costs associated with CVAD complications average at $2327 (AUD, 2020) per episode. Further investment in key diverse practice areas, including new CVAD types, CVAD pathology-based occlusion and dislodgment strategies, the appropriate use of device types, and tip-positioning technologies, will likely lead to extensive benefit."],"journal":["Pediatric research"],"pagination":["1381-1390"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC9700519"],"repository":["biostudies-literature"],"pubmed_title":["Pediatric central venous access devices: practice, performance, and costs."],"pmcid":["PMC9700519"],"pubmed_authors":["Kleidon TM","Schults J","Cooke M","Paterson R","Ullman AJ","Rickard CM","Takashima MD","Saiyed M","Cattanach P","Chopra V","Gibson V","Byrnes J"],"additional_accession":[]},"is_claimable":false,"name":"Pediatric central venous access devices: practice, performance, and costs.","description":"<h4>Background</h4>Healthcare delivery is reliant on a functional central venous access device (CVAD), but the knowledge surrounding the burden of pediatric CVAD-associated harm is limited.<h4>Methods</h4>A prospective cohort study at a tertiary-referral pediatric hospital in Australia. Children <18 years undergoing insertion of a CVAD were screened from the operating theatre and intensive care unit records, then assessed bi-weekly for up to 3 months. Outcomes were CVAD failure and complications, and associated healthcare costs (cost of complications).<h4>Results</h4>163 patients with 200 CVADs were recruited and followed for 6993 catheter days, with peripherally inserted central catheters most common (n = 119; 60%). CVAD failure occurred in 20% of devices (n = 30; 95% CI: 15-26), at an incidence rate (IR) of 5.72 per 1000 catheter days (95% CI: 4.09-7.78). CVAD complications were evident in 43% of all CVADs (n = 86; 95% CI: 36-50), at a rate of 12.29 per 1000 catheter days (95% CI: 9.84-15.16). CVAD failure costs were A$826 per episode, and A$165,372 per 1000 CVADs. Comparisons between current and recommended practice revealed inconsistent use of ultrasound guidance for insertion, sub-optimal tip-positioning, and appropriate device selection.<h4>Conclusions</h4>CVAD complications and failures represent substantial burdens to children and healthcare. Future efforts need to focus on the inconsistent use of best practices.<h4>Impact</h4>Current surveillance of central venous access device (CVAD) performance is likely under-estimating actual burden on pediatric patients and the healthcare system. CVAD failure due to complication was evident in 20% of CVADs. Costs associated with CVAD complications average at $2327 (AUD, 2020) per episode. Further investment in key diverse practice areas, including new CVAD types, CVAD pathology-based occlusion and dislodgment strategies, the appropriate use of device types, and tip-positioning technologies, will likely lead to extensive benefit.","dates":{"release":"2022-01-01T00:00:00Z","publication":"2022 Nov","modification":"2025-04-04T22:36:30.723Z","creation":"2025-04-04T22:36:30.723Z"},"accession":"S-EPMC9700519","cross_references":{"pubmed":["35136199"],"doi":["10.1038/s41390-022-01977-1"]}}