{"database":"biostudies-literature","file_versions":[],"scores":null,"additional":{"omics_type":["Unknown"],"volume":["37(1)"],"submitter":["Staelens AS"],"pubmed_abstract":["The gold standard to measure intra-abdominal pressure (IAP) is intra-vesical measurement via the urinary bladder. However, this technique is restricted in ambulatory settings because of the risk of iatrogenic urinary tract infections. Rectal IAP measurements (IAP<sub>rect</sub>) may overcome these limitations, but requires validation. This validation study compares the IAP<sub>rect</sub> technique against gold standard intra-vesical IAP measurements (IAP<sub>ves</sub>). IAP<sub>rect</sub> using an air-filled balloon catheter and IAP<sub>ves</sub> using Foley Manometer Low Volume were measured simultaneously in sedated and ventilated patients. Measurements were performed twice in different positions (supine and HOB 45° elevated head of bed) and with an external abdominal pressure belt. Sixt"],"journal":["Journal of clinical monitoring and computing"],"pagination":["287-296"],"full_dataset_link":["https://www.ebi.ac.uk/biostudies/studies/S-EPMC9852189"],"repository":["biostudies-literature"],"pubmed_title":["Is it feasible to measure intra-abdominal pressure using a balloon-tipped rectal catheter? Results of a validation study."],"pmcid":["PMC9852189"],"pubmed_authors":["Staelens AS","Gyselaers W","Van Regenmortel N","Christiaens S","Heymans A","Malbrain MLNG"],"additional_accession":[]},"is_claimable":false,"name":"Is it feasible to measure intra-abdominal pressure using a balloon-tipped rectal catheter? Results of a validation study.","description":"The gold standard to measure intra-abdominal pressure (IAP) is intra-vesical measurement via the urinary bladder. However, this technique is restricted in ambulatory settings because of the risk of iatrogenic urinary tract infections. Rectal IAP measurements (IAP<sub>rect</sub>) may overcome these limitations, but requires validation. This validation study compares the IAP<sub>rect</sub> technique against gold standard intra-vesical IAP measurements (IAP<sub>ves</sub>). IAP<sub>rect</sub> using an air-filled balloon catheter and IAP<sub>ves</sub> using Foley Manometer Low Volume were measured simultaneously in sedated and ventilated patients. Measurements were performed twice in different positions (supine and HOB 45° elevated head of bed) and with an external abdominal pressure belt. Sixt","dates":{"release":"2023-01-01T00:00:00Z","publication":"2023 Feb","modification":"2025-04-27T01:44:20.379Z","creation":"2024-11-21T01:04:37.943Z"},"accession":"S-EPMC9852189","cross_references":{"pubmed":["35907136"],"doi":["10.1007/s10877-022-00890-6"]}}