<HashMap><database>MetaboLights</database><file_versions><headers><Content-Type>application/xml</Content-Type></headers><body><files><Tabular>ftp://ftp.ebi.ac.uk/pub/databases/metabolights/studies/public/MTBLS14362/m_MTBLS14362_FIA-MS_positive__v2_maf.tsv</Tabular><Txt>ftp://ftp.ebi.ac.uk/pub/databases/metabolights/studies/public/MTBLS14362/s_MTBLS14362.txt</Txt><Txt>ftp://ftp.ebi.ac.uk/pub/databases/metabolights/studies/public/MTBLS14362/a_MTBLS14362_FIA-MS_positive_.txt</Txt><Txt>ftp://ftp.ebi.ac.uk/pub/databases/metabolights/studies/public/MTBLS14362/i_Investigation.txt</Txt></files><type>primary</type></body><statusCode>OK</statusCode><statusCodeValue>200</statusCodeValue></file_versions><scores/><additional><ftp_download_link>ftp://ftp.ebi.ac.uk/pub/databases/metabolights/studies/public/MTBLS14362</ftp_download_link><metabolite_identification_protocol>&lt;p>We developed an in-house processing pipeline for the untargeted data processing of the converted mzML files.&lt;/p></metabolite_identification_protocol><repository>MetaboLights</repository><study_status>Public</study_status><ptm_modification></ptm_modification><instrument_platform>Flow injection analysis MS - positive</instrument_platform><publication>MetaboFIMS: An automated workflow for fast and sensitive metabolic screening of large patient cohorts.</publication><submitter_name>Fabian Constantin Schmitt</submitter_name><submitter_affiliation>University Medical Center of the Johannes Gutenberg University Mainz</submitter_affiliation><flow_injection_analysis_protocol>&lt;p>We used the Agilent 1290 Infinity II LC for FI-MS by bridging the column department using a connector.&lt;/p></flow_injection_analysis_protocol><organism_part>blood plasma</organism_part><organism_part>solvent</organism_part><technology_type>mass spectrometry assay</technology_type><disease></disease><extraction_protocol>&lt;p>In brief a standard methanol extraction was used.&lt;/p></extraction_protocol><organism>blank</organism><organism>SRM (human)</organism><full_dataset_link>https://www.ebi.ac.uk/metabolights/MTBLS14362</full_dataset_link><author>Fabian Constantin Schmitt. schmittf@uni-mainz.de.</author><author>Thierry Schmidlin. University Medical Center of the Johannes Gutenberg University Mainz. schmidlt@uni-mainz.de.</author><data_transformation_protocol>&lt;p>We used ProteoWizard MSConvert for conversion of Sciex vendor format .wiff2 to either mzML or mzXML.&lt;/p></data_transformation_protocol><study_factor>Spray temperature</study_factor><study_factor>Spray voltage</study_factor><study_factor>Solvent condition</study_factor><submitter_email>schmittf@uni-mainz.de</submitter_email><sample_collection_protocol>&lt;p>NIST SRM 1950 was bought and used for method development of the FI-MS pipeline.&lt;/p></sample_collection_protocol><omics_type>Metabolomics</omics_type><study_design>Metabolomics</study_design><study_design>untargeted analysis</study_design><study_design>Flow Injection Analysis</study_design><study_design>solvent blank</study_design><study_design>ZenoTOF 7600</study_design><study_design>SRM (human)</study_design><study_design>experimental sample</study_design><study_design>untargeted metabolite profiling</study_design><study_design>data processing software</study_design><study_design>blood plasma</study_design><study_design>experimental blank</study_design><study_design>Solvent</study_design><study_design>SCIEX</study_design><curator_keywords>Metabolomics</curator_keywords><curator_keywords>untargeted analysis</curator_keywords><curator_keywords>Flow Injection Analysis</curator_keywords><curator_keywords>solvent blank</curator_keywords><curator_keywords>ZenoTOF 7600</curator_keywords><curator_keywords>SRM (human)</curator_keywords><curator_keywords>experimental sample</curator_keywords><curator_keywords>untargeted metabolite profiling</curator_keywords><curator_keywords>data processing software</curator_keywords><curator_keywords>blood plasma</curator_keywords><curator_keywords>experimental blank</curator_keywords><curator_keywords>SCIEX</curator_keywords><curator_keywords>Solvent</curator_keywords><mass_spectrometry_protocol>&lt;p>A Sciex ZenoTOF 7600 was used for MS1 only acquisition of FI-MS data.&lt;/p></mass_spectrometry_protocol><metabolite_name>Taurine</metabolite_name><metabolite_name>Lysine</metabolite_name><metabolite_name>glutamine</metabolite_name><metabolite_name>SEE XLSX</metabolite_name></additional><is_claimable>false</is_claimable><name>MetaboFIMS: An automated workflow for fast and sensitive metabolic screening of large patient cohorts</name><description>Development of a fully untargeted FI-MS processing pipeline.</description><dates><publication>2026-04-24</publication><submission>2026-04-24</submission></dates><accession>MTBLS14362</accession><cross_references><MetaboLights>MTBLC28300</MetaboLights><MetaboLights>MTBLC25094</MetaboLights><MetaboLights>MTBLC15891</MetaboLights><ChEBI>CHEBI:28300</ChEBI><ChEBI>CHEBI:25094</ChEBI><ChEBI>CHEBI:15891</ChEBI></cross_references></HashMap>