Low-intensity low-frequency ultrasound mediates riboflavin delivery during corneal crosslinking.


ABSTRACT: We employed the mechanical effect from 40 kHz ultrasound (US) to improve the delivery of riboflavin into corneal stroma for collagen crosslinking, which can benefit the treatment of keratoconus and other corneal ectasias. Experiments were conducted, first with porcine corneas ex vivo and then with New Zealand white rabbits in vivo, at varying mechanical index (MI) and sonication time. Results showed that 15 min of US applied on the cornea at MI = 0.8 in the presence of 0.5% of riboflavin solution enabled its delivery to deeper corneal stroma. Excessive heat was removed by a cooling setup to negate the thermal effect. The corneal absorption amount and penetration of riboflavin through cornea as detected by fluorotron, as well as the enhancement of corneal stiffness as measured by Young's mo