Unknown

Dataset Information

0

Prediction of humoral and cellular immune response to COVID-19 mRNA vaccination by TTV load in kidney transplant recipients and hemodialysis patients.


ABSTRACT:

Background

Immunosuppressed individuals such as kidney transplant recipients (KTR) and hemodialysis patients (DP) show impaired immune responses to COVID-19 vaccination. Plasma Torque Teno Virus (TTV) DNA load is used as surrogate for the individual degree of immunosuppression. We now assessed the association of TTV load at time of COVID-19 vaccination with humoral and cellular immune response rates to vaccination in KTR, DP, and healthy medical personnel (MP).

Methods

A total of 100 KTR, 115 DP and 54 MP were included. All were SARS-CoV-2 seronegative at the time of vaccination with either BNT162b2 or mRNA-1273. Plasma TTV loads were assessed at the time of first vaccination. After two-dose vaccination, seroconversion (de novo detection of SARS-CoV-2 S1-IgA and/or IgG) was determined. In addition, cellular responses as assessed by interferon γ release and neutralizing antibodies were assessed in a subset of participants. ROC analyses were performed to define TTV load cut-offs predicting specific immune responses to vaccination.

Results

Plasma TTV loads at the time of first vaccination were negatively associated with seroconversion after two-dose vaccination in KTR (OR 0.87, 95% CI 0.76-0.99). TTV loads were significantly lower in KTR who developed humoral and cellular immune responses to vaccination compared to non-responders (p = 0.0411 and 0.0030, respectively). Of patients with TTV loads above 106 copies/ml, none developed cellular immune responses against SARS-CoV-2, and only 2 of 17 (12%) seroconverted in response to vaccination.

Conclusion

Plasma TTV loads at the time of first vaccination in immunosuppressed individuals may be useful to predict individual vaccine-specific immune responses.

SUBMITTER: Graninger M 

PROVIDER: S-EPMC10036154 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Prediction of humoral and cellular immune response to COVID-19 mRNA vaccination by TTV load in kidney transplant recipients and hemodialysis patients.

Graninger Marianne M   Stumpf Julian J   Bond Gregor G   Görzer Irene I   Springer David N DN   Kessel Friederike F   Kröger Hannah H   Frank Kerstin K   Tonn Torsten T   Hugo Christian C   Puchhammer-Stöckl Elisabeth E  

Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology 20230324


<h4>Background</h4>Immunosuppressed individuals such as kidney transplant recipients (KTR) and hemodialysis patients (DP) show impaired immune responses to COVID-19 vaccination. Plasma Torque Teno Virus (TTV) DNA load is used as surrogate for the individual degree of immunosuppression. We now assessed the association of TTV load at time of COVID-19 vaccination with humoral and cellular immune response rates to vaccination in KTR, DP, and healthy medical personnel (MP).<h4>Methods</h4>A total of  ...[more]

Similar Datasets

| S-EPMC8222867 | biostudies-literature
| S-EPMC10102365 | biostudies-literature
| S-EPMC8780885 | biostudies-literature
| S-EPMC8585082 | biostudies-literature
| S-EPMC9383945 | biostudies-literature
| S-EPMC9090237 | biostudies-literature
| S-EPMC8279581 | biostudies-literature
| S-EPMC8436382 | biostudies-literature
| S-EPMC9911984 | biostudies-literature
| S-EPMC8537291 | biostudies-literature