Unknown

Dataset Information

0

Differences in Outflow Facility Between Angiographically Identified High- Versus Low-Flow Regions of the Conventional Outflow Pathways in Porcine Eyes.


ABSTRACT:

Purpose

To investigate differences in outflow facility between angiographically determined high- and low-flow segments of the conventional outflow pathway in porcine eyes.

Methods

Porcine anterior segments (n = 14) were mounted in a perfusion chamber and perfused using Dulbecco's phosphate buffered solution with glucose. Fluorescein angiography was performed to determine high- and low-flow regions of the conventional outflow pathways. The trabecular meshwork (TM) was occluded using cyanoacrylate glue, except for residual 5-mm TM areas that were either high or low flow at baseline, designating these eyes as "residual high-flow" or "residual low-flow" eyes. Subsequently, outflow was quantitatively reassessed and compared between residual high-flow and residual low-flow eyes followed by indocyanine green angiography.

Results

Fluorescein aqueous angiography demonstrated high-flow and low-flow regions. Baseline outflow facilities were 0.320 ± 0.08 and 0.328 ± 0.10 µL/min/mmHg (P = 0.676) in residual high-flow and residual low-flow eyes before TM occlusion, respectively. After partial trabecular meshwork occlusion, outflow facility decreased to 0.209 ± 0.07 µL/min/mmHg (-32.66% ± 19.53%) and 0.114 ± 0.08 µL/min/mmHg (-66.57% ± 23.08%) in residual high- and low-flow eyes (P = 0.035), respectively. There was a significant difference in the resulting IOP increase (P = 0.034).

Conclusions

Angiographically determined high- and low-flow regions in the conventional outflow pathways differ in their segmental outflow facility; thus, there is an uneven distribution of local outflow facility across different parts of the TM.

SUBMITTER: Strohmaier CA 

PROVIDER: S-EPMC10043501 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Differences in Outflow Facility Between Angiographically Identified High- Versus Low-Flow Regions of the Conventional Outflow Pathways in Porcine Eyes.

Strohmaier Clemens A CA   McDonnell Fiona S FS   Zhang Xiaowei X   Wanderer Daniel D   Stamer W Daniel WD   Weinreb Robert N RN   Huang Alex S AS  

Investigative ophthalmology & visual science 20230301 3


<h4>Purpose</h4>To investigate differences in outflow facility between angiographically determined high- and low-flow segments of the conventional outflow pathway in porcine eyes.<h4>Methods</h4>Porcine anterior segments (n = 14) were mounted in a perfusion chamber and perfused using Dulbecco's phosphate buffered solution with glucose. Fluorescein angiography was performed to determine high- and low-flow regions of the conventional outflow pathways. The trabecular meshwork (TM) was occluded usin  ...[more]

Similar Datasets

| S-EPMC3428113 | biostudies-literature
| S-EPMC4811179 | biostudies-literature
| S-EPMC5374885 | biostudies-literature
| S-EPMC6548641 | biostudies-literature
| S-EPMC5014700 | biostudies-literature
| S-EPMC6195566 | biostudies-literature
| S-EPMC10662726 | biostudies-literature
| S-EPMC5939687 | biostudies-literature
| S-EPMC4780770 | biostudies-literature
| S-EPMC5774255 | biostudies-literature