Evaluation of Long-Term Flow Controller for Monitoring Gases and Vapors in Buildings Impacted by Vapor Intrusion.
Ontology highlight
ABSTRACT: This study evaluated the use of a long-term capillary flow controller paired with an evacuated canister for indoor air exposure monitoring in a vapor intrusion (VI) environment with trichloroethylene in comparison to the traditional method utilizing a diaphragm flow controller. Traditionally, air sampling with 6 L evacuated canisters equipped with diaphragm flow controllers has been best suited for 8 to 24 h samples. New advances in capillary flow controllers can extend sampling to up to 3 weeks by reducing flow rates to 0.1 milliliters min-1. During six 2 wk sampling events, conventional diaphragm flow controller canisters were used to collect 24 h samples simultaneously with capillary flow controllers collecting 2 wk samples. Testing was performed at four indoor locations in b
SUBMITTER: Rossner A