ABSTRACT: Background
Through its helical centreline geometry, the BioMimics 3D vascular stent system is designed for the mobile femoropopliteal region, aiming to improve long-term patency and the risk of stent fractures.Methods
MIMICS 3D is a prospective, European, multi-centre, observational registry to evaluate the BioMimics 3D stent in a real-world population through 3 years. A propensity-matched comparison was performed to investigate the effect of the additional use of drug-coated balloons (DCB).Results
The MIMICS 3D registry enrolled 507 patients (518 lesion, length 125.9 ± 91.0 mm). At 3 years, the overall survival was 85.2%, freedom from major amputation 98.5%, freedom from clinically driven target lesion revascularisation 78.0%, and primary patency 70.2%. The propens