ABSTRACT: Background
To objectively measure with an eye tracker both eye movement conjugacy and gaze direction in different positions when performing the Hess Lancaster Screen Test (HLST) in a sample of control subjects without binocular dysfunction and compare the results with those of the traditional subjective HLST performance.Methods
The sample was selected avoiding subjects who suffered from suppression of one of the two eyes, visual acuity less than 20/25 on the Snellen chart in each eye, strabismus, or any symptom of binocular dysfunction that could alter the results. While performing the HLST, the examiner wrote down each of the points on a template in a traditional way while the eye tracker (Tobii Pro Fusion, Tobii AB, Danderyd, Sweden), placed in front of the subject, took