Unknown

Dataset Information

Evaluating corrected carotid flow time as a non-invasive parameter for trending cardiac output and stroke volume in cardiac surgery patients.


ABSTRACT:

Purpose

The corrected carotid flow time (ccFT) is derived from a pulsed-wave Doppler signal at the common carotid artery. Several equations are currently used to calculate ccFT. Its ability to assess the intravascular volume status non-invasively has recently been investigated. The purpose of this study was to evaluate the correlation and trending ability of ccFT with invasive cardiac output (CO) and stroke volume (SV) measurements.

Methods

Eighteen cardiac surgery patients were included in this prospective observational study. ccFT measurements were obtained at three time points: after induction of anesthesia (T1), after a passive leg raise (T2), and post-bypass (T3). Simultaneously, CO and SV were measured by calibrated pulse contour analysis. Three different equations (Ba

SUBMITTER: van Houte J 

PROVIDER: S-EPMC10063698 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature