Unknown

Dataset Information

0

A molybdenum disulfide/nickel ferrite-modified voltammetric sensing platform for ultra-sensitive determination of clenbuterol under the presence of an external magnetic field.


ABSTRACT: The electrochemical behavior and sensing performance of an electrode modified with NiFe2O4 (NFO), MoS2, and MoS2-NFO were thoroughly investigated using CV, EIS, DPV, and CA measurements, respectively. MoS2-NFO/SPE provided a higher sensing performance towards the detection of clenbuterol (CLB) than other proposed electrodes. After optimization of pH and accumulation time, the current response recorded at MoS2-NFO/SPE linearly increased with an increase of CLB concentration in the range from 1 to 50 μM, corresponding to a LOD of 0.471 μM. In the presence of an external magnetic field, there were positive impacts not only on mass transfer, ionic/charge diffusion, and absorption capacity but also on the electrocatalytic ability for redox reactions of CLB. As a result, the linear range was widened to 0.5-50 μM and the LOD value was about 0.161 μM. Furthermore, stability, repeatability, and selectivity were assessed, emphasizing their high practical applicability.

SUBMITTER: Tien VM 

PROVIDER: S-EPMC10069232 | biostudies-literature | 2023 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

A molybdenum disulfide/nickel ferrite-modified voltammetric sensing platform for ultra-sensitive determination of clenbuterol under the presence of an external magnetic field.

Tien Van Manh VM   Ong Van Hoang VH   Pham Tuyet Nhung TN   Quang Hoa Nguyen N   Nguyen Thi Lan TL   Thang Pham Duc PD   Khanh Vinh Le L   Trinh Pham Thi Nhat PTN   Thanh Doan Thi Ngoc DTN   Tung Le Minh LM   Le Anh-Tuan AT   Le Anh-Tuan AT  

RSC advances 20230403 16


The electrochemical behavior and sensing performance of an electrode modified with NiFe<sub>2</sub>O<sub>4</sub> (NFO), MoS<sub>2</sub>, and MoS<sub>2</sub>-NFO were thoroughly investigated using CV, EIS, DPV, and CA measurements, respectively. MoS<sub>2</sub>-NFO/SPE provided a higher sensing performance towards the detection of clenbuterol (CLB) than other proposed electrodes. After optimization of pH and accumulation time, the current response recorded at MoS<sub>2</sub>-NFO/SPE linearly incr  ...[more]

Similar Datasets

| S-EPMC8664269 | biostudies-literature
2024-06-27 | GSE235996 | GEO
| S-EPMC5943342 | biostudies-literature
| S-EPMC4660040 | biostudies-literature
| S-EPMC7317841 | biostudies-literature