Unknown

Dataset Information

0

Anion Exchange Resin and Inorganic Anion Parameter Determination for Model Validation and Evaluation of Unintended Consequences during PFAS Treatment.


ABSTRACT: When implementing anion exchange (AEX) for per- and polyfluoroalkyl substances treatment, temporal drinking water quality changes from concurrent inorganic anion (IA) removal can create unintended consequences (e.g., corrosion control impacts). To understand potential effects, four drinking water-relevant IAs (bicarbonate, chloride, sulfate, and nitrate) and three gel-type, strong-base AEX resins were evaluated. Batch binary isotherm experiments provided estimates of IA selectivity with respect to chloride ( K x ∕ C ) for IA/resin combinations where bicarbonate < sulfate ≤ nitrate at studied conditions. A multi-IA batch experiment demonstrated that binary isotherm-determined K x ∕ C values predicted competitive behavior. Subsequent column experiments with and without natural organic matter (NOM) allowed for the validation of a new ion exchange column model (IEX-CM; https://github.com/USEPA/Water_Treatment_Models). IA breakthrough was well-simulated using binary isotherm-determined K x ∕ C values and was minimally impacted by NOM. Initial AEX effluent water quality changes with corrosion implications included increased chloride and decreased sulfate and bicarbonate concentrations, resulting in elevated chloride-to-sulfate mass ratios (CSMRs) and Larson ratios (LRs) and depressed pH until the complete breakthrough of the relevant IA(s). IEX-CM utility was further illustrated by simulating the treatment of low-IA source water and a change in the source water to understand the resulting duration of changes in IAs and water quality parameters.

SUBMITTER: Smith SJ 

PROVIDER: S-EPMC10078613 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Anion Exchange Resin and Inorganic Anion Parameter Determination for Model Validation and Evaluation of Unintended Consequences during PFAS Treatment.

Smith Samantha J SJ   Wahman David G DG   Kleiner Eric J EJ   Abulikemu Gulizhaer G   Stebel Eva K EK   Gray Brooke N BN   Datsov Boris B   Crone Brian C BC   Taylor Rose D RD   Womack Erika E   Gastaldo Cameron X CX   Sorial George G   Lytle Darren D   Pressman Jonathan G JG   Haupert Levi M LM  

ACS ES&T water 20230101 2


When implementing anion exchange (AEX) for per- and polyfluoroalkyl substances treatment, temporal drinking water quality changes from concurrent inorganic anion (IA) removal can create unintended consequences (e.g., corrosion control impacts). To understand potential effects, four drinking water-relevant IAs (bicarbonate, chloride, sulfate, and nitrate) and three gel-type, strong-base AEX resins were evaluated. Batch binary isotherm experiments provided estimates of IA selectivity with respect  ...[more]

Similar Datasets

| S-EPMC8374359 | biostudies-literature
| S-EPMC6238712 | biostudies-literature
| S-EPMC5677403 | biostudies-literature
| S-EPMC11501922 | biostudies-literature
| S-EPMC9898221 | biostudies-literature
| S-EPMC6781013 | biostudies-literature
| S-EPMC4423237 | biostudies-literature
| S-EPMC6004612 | biostudies-literature
| S-EPMC10059923 | biostudies-literature
| S-EPMC9823821 | biostudies-literature