Unknown

Dataset Information

0

Randomized evaluation of redo ablation procedures of atrial fibrillation with focal impulse and rotor modulation-guided procedures: the REDO-FIRM study.


ABSTRACT:

Aims

REDO-FIRM evaluated safety and effectiveness of conventional vs. focal impulse and rotor modulation (FIRM)-guided ablation of recurrent persistent or paroxysmal atrial fibrillation (AF) after an initial AF ablation procedure.

Methods and results

This prospective, multicentre, randomized study included patients with a single prior AF ablation, but with recurrent AF and reconnected pulmonary veins (PVs). Conventional ablation generally included PV re-isolation; however, additional ablation was permitted per physician discretion. In the FIRM arm, beyond PV re-isolation, basket catheter-based FIRM mapping created dynamic animations of putative rotors, which were targeted for ablation. Between May 2016 and July 2019, 269 subjects were randomized, with 243 subjects completing 12-month follow-up. Ablation beyond re-pulmonary vein isolation, the FIRM vs. Conventional arms did not differ significantly: cavo-tricuspid isthmus -9.0% vs. 15.3%, caval vein isolation -1.5% vs. 0.8%, non-PV trigger -2.2% vs. 3.8%, other -11.9% vs. 13.0%. Single procedure 12-month freedom from AF/atrial tachycardia/atrial flutter-recurrence was 63.3% (76/120) vs. 59.0% (72/122) in the FIRM and Conventional arms (P = 0.3503). Efficacy was similar in the paroxysmal and persistent AF subgroups (P = 0.22 and P = 0.48). The 10-day and 12-month safety endpoints were achieved in 93.3% vs. 93.8% (P = 0.89) and 88.4% vs. 93.4% (P = 0.22) in the FIRM and Conventional arms, respectively.

Conclusions

In REDO-FIRM, as compared to standard ablation, FIRM-guided ablation did not provide additional efficacy in redo ablation procedures, but FIRM-guided ablation was equally safe. Additional studies are necessary to identify any potential population able to benefit from FIRM-guided ablation.

SUBMITTER: Spitzer SG 

PROVIDER: S-EPMC10103554 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Randomized evaluation of redo ablation procedures of atrial fibrillation with focal impulse and rotor modulation-guided procedures: the REDO-FIRM study.

Spitzer Stefan G SG   Miller John M JM   Sommer Philipp P   Szili-Torok Tamas T   Szili-Torok Tamas T   Reddy Vivek Y VY   Nölker Georg G   Williams Chris C   Sarver Anne A   Wilber David J DJ  

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 20230201 1


<h4>Aims</h4>REDO-FIRM evaluated safety and effectiveness of conventional vs. focal impulse and rotor modulation (FIRM)-guided ablation of recurrent persistent or paroxysmal atrial fibrillation (AF) after an initial AF ablation procedure.<h4>Methods and results</h4>This prospective, multicentre, randomized study included patients with a single prior AF ablation, but with recurrent AF and reconnected pulmonary veins (PVs). Conventional ablation generally included PV re-isolation; however, additio  ...[more]

Similar Datasets

| S-EPMC3524347 | biostudies-literature
| S-EPMC3416917 | biostudies-literature
| S-EPMC8139814 | biostudies-literature
| S-EPMC10894399 | biostudies-literature
| S-EPMC10407168 | biostudies-literature
| S-EPMC10287997 | biostudies-literature
| S-EPMC3703494 | biostudies-literature
| S-EPMC4048536 | biostudies-literature
| S-EPMC10636443 | biostudies-literature