Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study.


ABSTRACT:

Background

Few studies have compared the use of transabdominal ultrasound (TAUS) and magnetic resonance imaging (MRI) to measure prostate volume (PV). In this study, we evaluate the accuracy and reliability of PV measured by TAUS and MRI.

Methods

A total of 106 patients who underwent TAUS and MRI prior to radical prostatectomy were retrospectively analyzed. The TAUS-based and MRI-based PV were calculated using the ellipsoid formula. The specimen volume measured by the water-displacement method was used as a reference standard. Correlation analysis and intraclass correlation coefficients (ICC) were performed to compare different measurement methods and Bland Altman plots were drawn to assess the agreement.

Results

There was a high degree of correlation and agreement be

SUBMITTER: Guo S 

PROVIDER: S-EPMC10111778 | biostudies-literature | 2023 Apr