ABSTRACT: In the current investigation, the comparative study of cocoyam bioflocculant (CYBF) and chemical flocculant for the removal of heavy metals, COD, BOD, TDS, TSS, sulphate and nitrate from tannery effluent, and dyes from synthetic dye wastewater were examined. Different analytical techniques, including Fourier transforms infrared (FTIR), X-ray powder diffraction (XRD), Scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDX), were used to characterise the extracted bioflocculant. FTIR spectral measurement of the bioflocculant demonstrated the presence of hydroxyl, carboxyl, and amino groups. By using bioflocculant, the highest removal of TSS (85.5%), TDS (76.2%), BOD (74%), COD (50.5%), sulphate (54.4%), nitrate (52%), Lead (65%), Chromium (60%), Nickel (57.9%), from tann