ABSTRACT: Background
For proton therapy, a relative biological effectiveness (RBE) of 1.1 has broadly been applied clinically. However, as unexpected toxicities have been observed by the end of the proton tracks, variable RBE models have been proposed. Typically, the dose-averaged linear energy transfer (LETd ) has been used as an input variable for these models but the way the LETd was defined, calculated, or determined was not always consistent, potentially impacting the corresponding RBE value.Purpose
This study compares consistently calculated LETd with other quantities as input variables for a phenomenological RBE model and attempts to determine which quantity that can best predicts proton RBE. The comparison was performed within the frame of int